IZOLACE PROTI VODĚ A ZEMNÍ VLHKOSTI - HYDROIZOLACE. VLIV VODY NA STAVEBNÍ KONSTRUKCE: - KCE NASAKUJÍ VLHKOST A VODU / VLASTNOST STAV. MATER./ URČENO MÍROU TLAKU VODY A MNOŽSTVÍM VODY - DOCHÁZÍ K PORUŠOVÁNÍ KCÍ NOSNÝCH I DOPLŇKOVÝCH, KE ZTRÁTĚ POŽADOVANÝCH VLASTNOSTÍ - ZHORŠENÍ HYGIENICKÝCH POMĚRŮ A ŽIVOTNÍHO PROSTŘEDÍ - PLÍSNĚ, HOUBY HYDROIZOLACE ZAMEZUJÍ VNIKNUTÍ ŠKODLIVÉHO MNOŽSTVÍ ZEMNÍ VLHKOSTI, SPODNÍ VODY A DEŠŤOVÉ VODY Z EXTERIÉRU A VOLNÉ VODY, VOLNÉ VODY A VODNÍ PÁRY Z INTERIÉRU DO STAVEBNÍ KONSTRUKCE.
HYDROIZOLACE SPODNÍ STAVBY VODA V ZEMINĚ. A. VODA V PROVZDUŠNĚNÉ / AERAČNÍ / ZÓNĚ PROSAKUJÍCÍ - GRAVITAČNÍ - V PÓRECH VELKÝCH PRŮŘEZŮ VODA PROTÉKÁ SMĚREM K HLADINĚ PODZEMNÍ VODY VZLÍNAJÍCÍ - KAPILÁRNÍ - SOUVISÍ S HLADINOU PODZEMNÍ VODY A VYSTUPUJE NAD JEJÍ HLADINU VLIVEM KAPILÁRNÍ SÍLY /PÓROVITOST,ZRNITOST / B. VODA PODZEMNÍ GRAVITAČNÍ VODA NARAZÍ NA NEPROSTUPNOU VRSTVU / HLADINA PODZEMNÍ VODY / SCHÉMA PROSTUPU VODY ZEMINOU
PRŮZKUM STAVENIŠTĚ PRŮZKUM GEOLOGICKÝ A HYDROGEOLOGICKÝ GEOLOGICKÝ - VRTANÉ A KOPANÉ SONDY SLOŽENÍ ZÁKLADOVÉ PŮDY, PROPUSTNOST, GEOLOGICKÝ SLED VRSTEV, CHEMICKÉ SLOŽENÍ ZEMINY HYDROGEOLOGICKÝ- STUPEŇ VLHKOSTI ZEMINY /ZÁKL. PŮDY/ HLOUBKA VODNÍCH TOKŮ A JEJICH INTENZITA VÝŠKA HLADINY PODZEMNÍ VODY, CHEM. SLOŽENÍ VODY + DALŠÍ VLASTNOSTI VODY OVLIVŇUJÍCÍ BUDOUCÍ STAVBU ROZDĚLENÍ VODY DO KATEGORIÍ VOLBA DRUHU HYDROIZOLACE / MATERIÁL / + ZPŮSOBU PROVEDENÍ / TECHNOLOGIE / I. KATEGORIE TLAKOVÁ VODA / IZOLACE ODOLÁVAJÍCÍ TLAKU VODY / II. KATEGORIE IZOLACE PROTI PROSAKUJÍCÍ VODĚ / ZVÝŠENÁ ZEMNÍ VLHKOST, BEZTLAKOVÁ VODA, SKLONĚNÉ PLOCHY/ III. KATEGORIE ZEMNÍ VLHKOST ZVLÁŠTNÍ PŘÍPADY PRO NEPROPUSTNÉ ZEMINY: DO 2 M OD U.T. IZOLACE PROTI TLAKOVÉ VODĚ DO 0,02MPA OD 2 M OD U.T. IZOLACE PROTI TLAKOVÉ VODĚ OD 0,02MPA NAD TERÉNEM DO 300 MM IZOLACE PROTI ZEMNÍ VLHKOSTI RADĚJI ZVÝŠENÉ ZEMNÍ VLHKOSTI
KONSTRUKČNÍ PRINCIPY NOSNÝ PODKLAD IZOLAČNÍ POVLAK IZOLAČNÍ PLÁŠŤ NOSNÝ PODKLAD ROVNÝ BEZ TRHLIN MINIMÁLNÍ TLOUŠŤKA 80 MM HRANY, KOUTY, ZAOBLENY / MIN. R - FABION / NÁTĚROVÉ IZOLAČNÍ HMOTY POVLAKY, PÁSY R = 20MM R = 40-50MM
IZOLAČNÍ POVLAK /,, VLASTNÍ HYDROIZOLACE / SPOJITĚ OBKLOPUJE CELOU ČÁST OBJEKTU OHROŽENOU ZEMNÍ VLHKOSTÍ NEBO VOLNOU VODOU SEVŘEN TLAKEM IZOLAČNÍHO PLÁŠTĚ NEBO SPECIÁLNÍMI KOTVAMI VODOROVNÁ IZOLACE - PROVEDENA NA NOSNÉM PODKLADU VODOROVNÁ NEBO SKLONITÁ / OPTIMÁLNĚ 45 PŘI MAX.DÉLCE SKLONU 2,5M / SVISLÁ IZOLACE - VNĚJŠÍ LÍC OBVODOVÉ STĚNY - DO TZV. IZOLAČNÍ VANY
IZOLAČNÍ VANA DO TZV. IZOLAČNÍ VANY SE PROVÁDÍ IZOLACE V PŘÍPADĚ NEMOŽNOSTI VYTVOŘENÍ VNĚJŠÍHO PRACOVNÍHO PROSTORU.DO OCHRANNÉ POMOCNÉ KCE, KTERÁ JE VYTVOŘENA VODOROVNOU PODKLADNÍ VRSTVOU / DNO VANY / A SVISLOU OBEZDÍVKOU NEBO MONIERKOU, T.J. TENKOSTĚNOU KONSTRUKCÍ ZE ŽELEZOBETONU / PLÁŠŤ VANY /.SVISLÁ IZOLACE SE PROVÁDÍ SOUČASNĚ S IZOLACÍ VODOROVNOU.DO ZAIZOLOVANÉ VANY SE NÁSLEDNĚ POSTAVÍ KCE SUTERÉNU.
SPOJE IZOLACÍ VODOTĚSNÉ PŘIPOJENÍ OKRAJŮ JEDNÉ NEBO NĚKOLIKA VRSTEV IZOLAČNÍHO POVLAKU.NEJVĚTŠÍ POZORNOST MUSÍ BÝT VĚNOVÁNA SPOJENÍ VODOROVNÉ A SVISLÉ IZOLACE,KTERÉ MŮŽE BÝT PROVEDENO SPOJEM ZPĚTNÝM NEBO OBRÁCENÝM. ZPĚTNÝ SPOJ - PROTISMĚRNÉ PŘIPOJENÍ IZOLAČNÍHO POVLAKU V NÁSLEDNÉ ETAPĚ.V PRVNÍ ETAPĚ SE PROVÁDÍ VODOROVNÁ IZOLACE, JEJÍŽ VRSTVY SE CHRÁNÍ PROVIZORNÍ OCHRANOU VRSTVOU / NAPŘ. Z BETONU, Z MALTY /. VE DRUHÉ ETAPĚ, PO PROVEDENÍ STĚNY SUTERÉNU, SE PROVIZORNÍ OCHRANNÁ VRSTVA ODSTRANÍ A NA VODOROVNOU IZOLACI SE NAPOJÍ PŘÍSLUŠNÉ VRSTVY IZOLACE SVISLÉ.HOTOVÝ ZPĚTNÝ SPOJ SE CHRÁNÍ VRSTVOU CEMENTOVÉ MALTY, NA NÍŽ SE VYBETONUJE ZÁKLAD PRO OBEZDÍVKU SVISLÉ IZOLACE. ZPĚTNÝ SPOJ SE POUŽÍVÁ PRO IZOLACE III. OBRÁCENÝ SPOJ - ETAPOVÉ NAPOJENÍ IZOLAČNÍHO POVLAKU VE SVISLÉ IZOLACI S OBRÁCENÝM PRACOVNÍM PROSTOREM V JEDNOTLIVÝCH ETAPÁCH. V PRVNÍ ETAPĚ SE PROVEDE IZOLAČNÍ POVLAK Z VNITŘNÍ STRANY OBJEKTU NA NÍZKOU IZOLAČNÍ VANU S PROVIZORNÍ NADEZDÍVKOU. PO POSTAVENÍ STĚNY SUTERÉNU SE PROVIZORNÍ NADEZDÍVKA ROZEBERE,HOTOVÁ IZOLACE SE PŘILEPÍ NA STĚNU OBJEKTU A NA NI SE PŘIPOJÍ DALŠÍ SVISLÁ IZOLACE. NEBO V PŘÍPADĚ NAPOJENÍ Z DRUHÉ STRANY KCE NEŽ PROBÍHALA PRVNÍ ETAPA OBRÁCENÝ SPOJ JE ZÁVAZNÝ PRO IZOLACE I. KATEGORIE
IZOLAČNÍ PLÁŠŤ VODOROVNÁ IZOLACE - VRSTVA BETONOVÉ MAZANINY O MINIMÁLNÍ TLOUŠŤCE 40 MM SVISLÁ IZOLACE NOPOVANÁ FOLIE PŘIZDÍVKA - Z OSTŘE PÁLENÝCH CIHEL O TL. 1/4 NEBO 1/2 CIHLY / PODLE VÝŠKY PŘIZDÍVKY / BETONOVÁ PŘÍČKA /MONIERKA/ - MINIMÁLNÍ VZDÁLENOST VÝZTUŽE A VLASTNÍ IZOLACE 50MM / IZOLACI NUTNO CHRÁNIT PŘI PROVÁDĚNÍ PROSTŘIKEM O TLOUŠŤCE 5-10MM / SEVŘENÍ IZOLACE POMOCÍ SPEC. KOTEV - NENÍ-LI MOŽNÉ ZAJISTIT SEVŘENÍ SVISLÉ IZOLACE ZEMNÍM TLAKEM / NAPŘ. NA STAVBÁCH V PROLUKÁCH NEBO NA STAVBÁCH PROVÁDĚNÝCH VE STĚNĚ SKALNÍHO PRŮLOMU / JE NUTNO IZOLACI SEVŘÍT MEZI STĚNU OBJEKTU A OCHRANNOU MONIERKOU POMOCÍ KOTEV.KOTVÍCÍ ČLÁNKY MAJÍ KOVOVÉ PŘÍRUBY /MEZI NĚŽ SE IZOLACE SEVŘE / A KOTEVNÍ PRO NASAZENÍ DO STĚNY OBJEKTU A DO MONIERKY
IZOLACE BUDOV NEPODSKLEPENÝCH U BUDOV NEPODSKLEPENÝCH SE OBVYKLE PROVÁDÍ POUZE IZOLACE STĚN A PODLAHY 1. NADZEMNÍHO PODLAŽÍ.UKLÁDÁ SE NA PODKLADNÍ BETONOVOU MAZANINU,PROVEDENOU NA ŠTĚRKOPÍSKOVÉ VRSTVĚ. IZOLACE NEPODSKLEPENÝCH BUDOV MÁ BÝT ULOŽENA MIN. 300MM NAD ÚROVNÍ TERÉNU. VLHKOST ZPŮSOBUJE PORUCHY SOKLŮ A JEJICH POVRCHOVÝCH ÚPRAV.PROTO MAJÍ BÝT SOKLY PROVEDENY Z MATERIÁLŮ, ODOLÁVAJÍCÍCH PŮSOBENÍ VODY, NAPŘ. Z BETONU SE ZAVÁZANÝM KAMENNÝM OBKLADEM NEBO SE IZOLUJÍ ASFALTOVÝM NÁTĚREM, PROVEDENÝM POD POVRCHOVOU ÚPRAVOU / NAPŘ. OMÍTKOU, OBKLADEM /. IZOLACE BUDOV PODSKLEPENÝCH IZOLACE SLOUPŮ
ASFALTOVÉ IZOLACE NEMOHOU PROBÍHAT POD ŽELEZOBETONOVÝMI SLOUPY / MAX. PŘÍPUSTNÉ NAPĚTÍ V TLAKU ASFALT. IZOLACÍ JE 0,5MPA /. PROTO SE PRO IZOLACI SLOUPŮ POUŽÍVAJÍ HYDROIZOLAČNÍ PŘEPÁŽKY - NAPŘ. TĚSNÍCÍ ZÁTKY Z VODOTĚSNÉHO BETONU / SNÍŽENÁ PEVNOST BETONU / VLOŽKY ZE SYNTETICKÝCH PRYSKYŘIC / NÁTĚRY, VYZTUŽENÉ TMELY - SKLENĚNÁ VLÁKNA / NÁCHÁZÍ-LI SE ZÁKLAD V AGRESIVNÍM PROSTŘEDÍ, JE NUTNÉ PROTI JEHO ÚČINKŮM IZOLOVAT CELOU KONSTRUKCI ZÁKLADŮ.IZOLACE MUSÍ BÝT CHRÁNĚNA PODKLADNÍM BETONEM S VRSTVOU LITÉHO ASFALTU A OBEZDÍVKOU Z OSTŘE PÁLENÝCH CIHEL, ZDĚNÝCH NA ASFALTOCEMENTOVOU MALTU. UKONČENÍ IZOLACÍ + DRENÁŽE VE SPODNÍ STAVBĚ JE NUTNO VYLOUČIT MOŽNOST ZATÉKÁNÍ VODY ZA SVISLOU IZOLACI.
SNIŽOVÁNÍ HLADINY PODZEMNÍ VODY ZJEDNODUŠENÍ PROVÁDĚNÍ KCE ZÁKLADŮ, SNÍŽENÍ RIZIKA OHROŽENÍ STAVBY VODOU A VLHKOSTÍ TRVALÉ TVAROVÁNÍ OBJEKTU / JINÉ KČNÍ ŘEŠENÍ OBJEKTU, NAPŘ. USTOUPIT OD PODLAŽÍ ZASAŽENÉHO HLADINOU PODZEMNÍ VODY / HYDROIZOLAČNÍ CLONA / UMĚLÉ VYTVOŘENÍ ZÁBRAN PŮSOBENÍ VODY NA OBJEKT ŠTĚTOVÉ STĚNY INJEKTOVÁNÍ ZEMINY JÍLOVITOCEMENTOVÉ, BENTONITOVÉ SMĚSI... TRVALÉ ODVODNĚNÍ ZÁKL. SPÁRY DRENÁŽOVÁNÍM TYTO ZPŮSOBY IZOLACÍ ZLEVŇUJÍ STAVBU. JE NUTNÁ DŮKLADNÁ PROJEKTOVÁ PŘÍPRAVA, ZNÁT HYDROGEOLOGICKÉ PODMÍNKY STAVBY. DOČASNÉ - DRENÁŽOVÁNÍ - PROVEDE SE ODVODNĚNÍ SPODNÍ STAVBY, PO PROVEDENÍ IZOLACE PROTI TLAKOVÉ VODĚ SE SNÍŽENÁ HLADINA ZRUŠÍ.
PROBLEMATIKA IZOLACE PROTI TLAKOVÉ VODĚ KCE NAVRŽENA NA ZÁKLADĚ: ZNALOSTI POVAHY STAV. POZEMKU ZNALOSTI VÝŠKY NEJVÝŠŠÍ HLADINY PODZEMNÍ VODY ZNALOSTI OBSAHU CHEM. PŘÍMĚSÍ MUSÍ BÝT PROVEDENA MINIMÁLNĚ 300 MM NAD NEJVYŠŠÍ HLADINU PODZEMNÍ VODY POUŽÍT VHODNÝ MATERIÁL URČENÝ NA IZOLACE PROTI TLAKOVÉ VODĚ POSTUP PŘI NAVRHOVÁNÍ KONSTRUKČNÍHO ŘEŠENÍ HYDROIZOLACÍ ZNALOST HYDROGEOLOGICKÝCH A GEOLOGICKÝCH PODMÍNEK V PŘÍPADĚ VYŠŠÍ HLADINY PODZEMNÍ VODY UVAŽIT VŠECHNA EXISTUJÍCÍ OPATŘENÍ / SNIŽENÍ HLADINY PODZEMNÍ VODY, ZMĚNA TVARU OBJEKTU.../ ZVOLIT VHODNÝ TVAR NOSNÉHO PODKLADNÍHO BETONU ZVOLIT VHODNÝ DRUH IZOLAČNÍHO MATERIÁLU NAVRHNOUT KČNÍ ŘEŠENÍ TAK, ABY ODPOVÍDALO VŠEM DOPORUČENÝM PRAVIDLŮM SAMOSTATNÁ PRÁCE: NAVRHNOUT ZPŮSOB IZOLOVÁNÍ NA ZADANOU SPODNÍ STAVBU
ZÁKLADNÍ HYDROIZOLAČNÍ MATERIÁLY HTTP://SLIDEPLAYER.CZ/SLIDE/3063381/ ASFALTOVÉ / ŽIVIČNÉ / MATERIÁLY ASFALTOVÉ PENETRAČNÍ LAKY - ROZTOKY VHODNÝCH DRUHŮ ASFALTŮ V ORGANICKÉM ROZPOUŠTĚDLE,POUŽÍVANÉ K PENETRACI / NAPOUŠTĚNÍ/ SUCHÝCH A OČIŠTĚNÝCH PODKLADŮ.PRONIKAJÍ DO PÓRŮ A VYTVÁŘEJÍ PODKLAD PRO ZAKOTVENÍ NÁSLEDNÉHO NÁTĚRU K PODKLADU. ASFALTOVÉ LAKY - NÁTĚRY PODKLADNÍ, SPOJOVACÍ, KRYCÍ ASFALTOVÉ TMELY - PRO IZOLAČNÍ VRSTVY, ZÁLIVKOVÉ HMOTY, LEPÍCÍ VRSTVY A POD. SPECIÁLNÍ SMĚSI ASFALTŮ A MINERÁLNÍCH MOUČEK SE POUŽÍVAJÍ PRO KYSELINO VZDORNÉ IZOLACE. ASFALTOVÉ IZOLAČNÍ PÁSY / ŽIVIČNÉ IZOLAČNÍ PÁSY / OXIDOVANÉ ASFALTY 95/35 MODIFIKOVANÉ ASFALTY SBS 160/220-25 JSOU TO PLOŠNÉ, ZPRAVIDLA SVINOVATELNÉ PÁSY, SESTÁVAJÍCÍ Z NOSNÉ VLOŽKY, ZPRAVIDLA IMPREGNOVANÉ ASFALTEM,PŘÍPADNĚ OPATŘENÉ KRYCÍMI ASFALTOVÝMI HMOTAMI V PODOBĚ TKANINY, LEPENKY, FOLIE A POD.. NOSNÉ VLOŽKY: - NASÁKAVÉ / JUTA, PAPÍR,... / - NENASÁKAVÉ / SKLENĚNÁ TKANINA, FOLIE PE, KOVOVÉ FOLIE.../ TYP A - / BEZ KRYCÍ VRSTVY / PÁS POUŽÍVANÝ JAKO IZOLAČNÍ VÝZTUŽNÁ VLOŽKA IZOLAČNÍCH POVLAKŮ, NOSNÁ VLOŽKA ASFALTOVÉHO PÁSU JE ZPRAVIDLA IMPREGNOVÁNA STAVEBNÍM IZOLAČNÍM OXIDOVANÝM ASFALTEM VLOŽKA H / NASÁKAVOST 30 HMOTNOSTNÍCH/ VLOŽKA SH / NASÁKAVOST 35 HMOTNOSTNÍCH / TYP R - / S KRYCÍ VRSTVOU DO 1MM / PÁS POUŽÍVANÝ JAKO HYDROIZOLAČNÍ VRSTVA IZOLAČNÍCH POVLAKŮ V KOMBINACI S NÁTĚRY ZA HORKA, NOSNÁ VLOŽKA ASFALTOVÉHO PÁSU JE OBOUSTRANĚ KRYTÁ ASFALTOVOU HMOTOU V TL. 1MM, S POVRCHOVOU ÚPRAVOU JEMNOZRNNÉHO MINERÁLNÍHO OBOUSRANNÉHO POSYPU, NEVHODNÝ PRO TRVALÉ POVLAKOVÉ KRYTINY BEZ KVALITNÍ OCHRANNÉ VRSTVY. TYP S - /ZESÍLENÁ KRYCÍ VRSTVA, VÍCE JAK 1MM / PÁS POUŽÍVANÝ JAKO PREFABRIKOVANÁ HYDROIZOLAČNÍ VRSTVA IZOLAČNÍCH POVLAKŮ, NOSNÁ VLOŽKA S AFALTOVÉHO PÁSU JE OBOUSTRANĚ KRYTÁ ASFALTOVOU HMOTOU TL. PŘES 1MM OBCHODNÍ NÁZVY VYBRANÝCH DRUHŮ ASF.IZOLAČNÍCH PÁSŮ S HLINÍKOVOU VLOŽKOU FOALBIT,BITALBIT ALFOBIT,BITAL,ALVENTBIT, S MĚDĚNOU VLOŽKOU S OLOVĚNOU VLOŽKOU PARADIAL, VERAL CUFOLBIT ADEPLOMB
IZOLACE Z PLASTŮ A PRYŽÍ FOLIE Z MĚKČENÉHO PVC ISOFOL, NOVOPLAST FOLIE POLYETYLENOVÉ /PE/ PENEFOL FOLIE PRYŽOVÉ, ETHYLÉN-PROPYLÉNOVÉ OPTIFOL PLASTOVÉ PROFILOVANÉ FOLIE DELTA FONDULINE