CAN bus sniffer

Podobné dokumenty
U2043B. Flasher, 30-m Shunt, Pilot Lamp to GND or V Batt. Description. Features. Ordering Information. Block Diagram

CAR2FMS Interface v2

FMS OEM CHIP V6+ CAR2BT CAR2COM CAR2USB

Only Children and Siblings: The Differences in Educational Attainment and Family Background

AUXILIARY RELAYS FOR TRIPPING APPLICATIONS

AUXILIARY RELAYS FOR RAILWAY SECTOR. Rolling Stock signalling

LED MOVING HEAD 108x3W RGBW STRONG User Manual

User documentation. M-functions

Operating guide 5417 Uniport

User documentation. Cycles, macro's and Q-parameters

2N LiftIP. IO Extender. Communicator for Lifts. Version

Czech-Russian relations and the perception of Russia by the Czech population

Nine9 | KL-TECH s.r.o. |

Днепр) Electrical Schematics

DC circuits with a single source

Lamina | KL-TECH s.r.o. |

2N Voice Alarm Station

ZEUS - HOMMEL KELLER| KL-TECH s.r.o. |

CAN SNIFFER. - technický popis -

VOŠ, SPŠ automobilní a technická. Mgr. Marie Šíchová. At the railway station

UŽIVATELSKÁ PŘÍRUČKA

CCD 90 MV Cameras (Firewire) CCD 90 MV Cameras (GigE) CCD 90 MV Cameras (USB 2.0)

2N LiftIP. Voice Alarm Station. Communicator for Lifts. Version

2N Lift8 Audio unit cabin universal

Litosil - application


Analýza dějů na rozhraní RS 232 C

Image Analysis and MATLAB. Jiří Militky

1. Maple - verze. 2. Maple - prostredi. Document Mode vs. Worksheet Mode

AirKIT TECHNICKÝ MANUÁL. TnG-AirKIT. Power. Run

INSTALLATION MANUAL PD

By David Cameron VE7LTD

SERVISNÍ MANUÁL PEGAS 250 E CEL OVO SERVICE MANUAL PEGAS 250 E CEL OVO

ŘÍZENÍ FYZIKÁLNÍHO PROCESU POČÍTAČEM

SERVICE MANUAL PEGAS 250 E CEL SERVISNÍ MANUÁL PEGAS 250 E CEL

18.VY_32_INOVACE_AJ_UMB18, Frázová slovesa.notebook. September 09, 2013

NAPÁJECÍ ZDROJE ČISTÝ VÝKON POWER SUPPLIES PURE POWER PROLUMIA

DATA SHEET. BC516 PNP Darlington transistor. technický list DISCRETE SEMICONDUCTORS Apr 23. Product specification Supersedes data of 1997 Apr 16

MG014-2 SERVISNÍ MANUÁL / SERVICE MANUAL ALFIN 150 TIG HF

GUIDELINES FOR CONNECTION TO FTP SERVER TO TRANSFER PRINTING DATA

MA251 (cz_en) Operating instructions. MA251 (cz_en) Montážní návod. Krimpovací kleště PV-CZM... pro MC3, MC4 a MC4-EVO 2

Boundary Scan JTAG (Joined Test Action Group) IEEE 1149.X Zápis do rozhraní



Řetězový pohon pro otevírání a zavírání ven výklopných oken, kyvných oken, světlíků a dovnitř sklopných oken ze dřeva, PVC a hliníku.

Škola: Střední škola obchodní, České Budějovice, Husova 9. Inovace a zkvalitnění výuky prostřednictvím ICT

SERVISNÍ MANUÁL PEGAS 200 AC- DC PULSE OVO SERVICE MANUAL PEGAS 200 AC- DC PULSE OVO

Soukromá střední odborná škola Frýdek-Místek, s.r.o.

1-AYKY. Instalační kabely s Al jádrem. Standard TP-KK-133/01, PNE Konstrukce. Použití. Vlastnosti. Installation cables with Al conductor

Switch on the appropriate breaker and verify that the light is working properly.

materiál č. šablony/č. sady/č. materiálu: Autor:

PRÁCE S UKÁZKAMI ODPOVĚDÍ MATURANTŮ NA DVD

Název společnosti: VPK, s.r.o. Vypracováno kým: Ing. Michal Troščak Telefon: Datum:

TR 311 TR 319, TR 331 TR 356

MG122-1 SERVISNÍ MANUÁL / SERVICE MANUAL ALFIN 171 W

PC/104, PC/104-Plus. 196 ept GmbH I Tel. +49 (0) / I Fax +49 (0) / I I

HYSLY Flex - JZ, OZ, OB, JB

BLATNÍKY A BEDNY NA NÁŘADÍ MUDGUARDS AND TOOLBOXES

Instalační kabely s Cu jádrem

NÁVOD NA OBSLUHU AKTUALIZACE SW

USER'S MANUAL FAN MOTOR DRIVER FMD-02

H2shop.cz. english česky

Standard VGA (Video Graphics Array)

20 ka / 1 s (dle typu cívky) přirozené

Uživatelská příručka. Xperia P TV Dock DK21

MAGNETICKÉ SNÍMAČE M/50 Pro kruhové, ISO/VDMA, VDMA kompakt a Lintra bezpístnicové válce a kluzné jednotky

:= = := :=.. := := := := ρ := := α := π α = α = := = :=

On-line datový list. AFS60I-Q4PK AFS/AFM60 Inox ABSOLUTNÍ ENKODÉR

MAXIMUM DC INPUT CURRENT NO LOAD CURRENT DRAW OVER LOAD / SHORT CIRCUIT OVER TEMPERATURE HIGH DC INPUT VOLTAGE DC INPUT VOLTAGE, VOLTS

Interface CAR2FMS v2 firmware CAN data generátor

MG019-2 SERVISNÍ MANUÁL / SERVICE MANUAL ALFIN 200 TIG HF

KUZMA. Zákaznický ceník platný od května 2014 včetně DPH 21% I.Tonearms

Měřič výkonu 1μW - 1kW. Power Meter 1μW - 1kW

Název společnosti: VPK, s.r.o. Vypracováno kým: Ing. Michal Troščak Telefon: Datum:


MG125-4 PEGAS 200 AC-DC PULSE SERVICE MANUAL

Návod k obsluze/user manual LAD2 Propojovací krabička/cable junction box

Byznys a obchodní záležitosti

NÁVOD K OBSLUZE LAN ovladač s relé

EtherNet/IP. 5pinové napájení 2x bezpečný digitální vstup

PLANAR - měřící servisní technika a monitoring zpětných směrů

Co je uvnitř - senzory a přístrojová technika v NXT robotech. Pavel Ripka katedra měření ČVUT

Caló. Made from the ground - keramická svítidla ze španělské manufaktury POTT - NeNo design Ltd.

VY_22_INOVACE_60 MODAL VERBS CAN, MUST

TechoLED H A N D B O O K

Nais. Made from the ground - keramická svítidla ze španělské manufaktury POTT - NeNo design Ltd.

chci se zeptat, kdy je šance dostat peníze z APL na žádost poslanou 15.1.

Pokyny k použití. Model-300. Napájecí zdroj. Návod na obsluhu Operating Instructions. se systémem Aquacontrol Napájací zdroj

1. Uvod 2. Maple - verze - Maple 18: Standard Worksheet (.mw) -!! my budeme pouzivat!! 3. Maple - prostredi Ikonky Poznamka: Priklad: >

NOPOVIC 1-CXKH-V B2cas1d0 a1 FE180 E60 P60-R PS60

Střední odborná škola a Střední odborné učiliště, Chrudim, Čáslavská

On-line datový list. AFS60I-S4PC AFS/AFM60 Inox ABSOLUTNÍ ENKODÉR

Citelis E5 SCR: P íznaky: Diagnóza:

Střední průmyslová škola strojnická Olomouc, tř.17. listopadu 49

Montážní návod Mounting instructions. Hydraulika / hydraulics Case Farmall U-Pro

Postup objednávky Microsoft Action Pack Subscription

Montážní návod Mounting instructions. Hydraulika / hydraulics Deutz Fahr 5100G

SpongeRo. Made from the ground - keramická svítidla ze španělské manufaktury POTT - NeNo design Ltd.

INSTALAČNÍ NÁVOD OPERATING INSTRUCTION

On-line datový list. AFS60I-BFAC AFS/AFM60 Inox ABSOLUTNÍ ENKODÉR

Transkript:

- Technical description - Contents: GENERAL DESCRIPTION 2 INSTALLATION 4 MOLEX CONNECTOR AND WIRE DESCRIPTION 5 Ing. David Španěl Mgr. Vítězslav Rejda 1 / 5 Verze dokumentu 1.10

General description When connecting external devices to CAN bus in the car or other system, there is always risk of influencing the communication on the bus because of this device. E.g. elementary mistake as incorrectly set bus speed, if the device is not in Listen only mode, disturbs the communication on the bus, thus the car control units report error and the car can be out of order. Listen only mode eliminates this risk, however, the error in software of the connected device or error of device settings/configuration can cause that this mode is not active and communication can be disturbed, e.g. message can be generated at the CAN bus that could have unpredictable consequences as extreme example. Other problem that can occur during connection directly to engine-can without using FMS gate or similar device approved by manufacturer of the car, is the electrical conductible connection with CAN bus. It violates guarantee conditions for the car and in case of accident, connected device could be considered to be the cause of the accident. On the other hand, connection directly to engine-can is in cars without FMS gate (with respect to the unavailability of the gate cars; or its high price) the only possibility how to read real kilometers, fuel tank level and so on at reasonable expense. In case of modern cars, reading from the engine-can provides more data then FMS gate. device allows data reading from CAN bus by means of tapping and signal reconstruction at the bus through its scanning from conductors through their insulation. is not conductibly connected with the car bus, thus, the conductors are not disturbed, and communication at this bus cannot be influenced. output is signal of CAN bus that can be connected to other device that has input of CAN bus, high speed type. Output CAN is of high speed type according to ISO 11898-2. Device works within the speed range of 83.3k 1Mbit. Scanned CAN can be of high speed type or low speed type. Device works with both variants of CAN. When using conductors of so called low speed CAN (11898-3 and ISO 11992-1), low speed CAN is transformed into high speed CAN at the output. Thus, it is also one-way converter of CAN low speed -> high speed. If the communication speed of the connected device is incorrectly set, no data is read. CAN errors are not sent to the car CAN bus. Short circuit of the CAN at connected device does not show itself at the car CAN. contains own pulse transformer with input power range 8-32 V. Thus, it is not requested to put in external stabilized voltage. Device consumption is 0.13 W. Dimensions of the device: 58 mm x 33 mm. There is proprietary electronics protected against humidity by means of epoxy layer on one side, and scanning surfaces and MOLEX connector on the other side. This connector can be replaced with 4cable harness upon request. CAN conductors in the car are fixed to the scanning surfaces by means of 2 fixation formulations and 2 plastic rivets. It is not possible to decompose those rivets without damage. After removal and subsequent montage, 2 / 5 Verze dokumentu 1.10

use new rivets. When using just for short-time measurement, it is possible to use clamping tapes. Connected device must be used in normal mode. In the Listen only mode, there is possibility of receiving of damaged packets. Packet reconstruction in device does not have to be always 100% with respect to ambient disturbance that is indicated in scanning surfaces. Some packets can be reconstructed incorrectly with respect to high disturbance, thus, the device must ignore them. Correct treatment of CAN bus errors in the connected device is connected with that (BUS OFF etc). Error rate is influenced also by place of connection to conductors in the car. can be connected also to blind branch up to 50 cm (in reality, this distance depends on topology of the car net and distance between individual ECUs). In case of connection to blind branch, higher error rate must be taken into account. However, high error rate is not a problem, because information on the car CAN bus is repeated so quickly that message failure is not perceptible. It must be emphasized that error packets only between and connected device have no (and can not have) influence on car CAN!!! 3 / 5 Verze dokumentu 1.10

Installation Device is connected to conductors in the car according to these steps: 1) Device must be installed in to the car so it cannot be in contact with water or other liquids. It is suitable to install it for example into the dashboard. Device can t be installed loosely to the engine compartment. 2) Fixation element is put between conductor CAN H and CAN L that puts out the conductors to requested spacing. 3) is added to this fixation element and all 2 pieces are joined by means of supplied plastic rivets. 4) Power is connected to the car and CAN of the connected device. 5) It is suitable not to connect the power permanently, so it could be controlled by signal 15 (ignition). 6) After installing, it is suitable to use e.g. USB2CAN device to control operation. 7) If doesn t work, you must check if the CAN H and CAN L conductors at the scanning surfaces are not switched. 8) If the error rate is high, you can move the to the different place at the CAN cable, farther from possible sources of disturbance (other conductors, electronics). Measured CAN bus H wire Plastic rivets Measured CAN bus L wire Fixation element 4 / 5 Verze dokumentu 1.10

MOLEX Connector and wire description Pin Description 1 Power 8-32V RED wire 2 GND WHITE or BLUE wire 3 CAN H BLACK wire 4 CAN L GREEN wire 5 / 5 Verze dokumentu 1.10