TECHNICAL MANUAL ACC-NET. PC - Controller Central unit with Ethernet interface



Podobné dokumenty
PC - Controller Centrální jednotka s rozhraním Ethernet TECHNICKÝ MANUÁL ACC-NET. Pro jednotky FUJITSU split a multisplit

PC - Controller Centrální jednotka s rozhraním RS-232 TECHNICKÝ MANUÁL ACC-RS. Pro jednotky FUJITSU split a multisplit

2N LiftIP. IO Extender. Communicator for Lifts. Version

Instalační manuál rev

HWg-STE zapojení konektorů

AirKIT TECHNICKÝ MANUÁL. TnG-AirKIT. Power. Run


USER'S MANUAL FAN MOTOR DRIVER FMD-02

Připojení internetového modulu econet300 Do regulátoru ecomax 810P3-L TOUCH.

Automatika na dávkování chemie automatic dosing

CCD 90 MV Cameras (Firewire) CCD 90 MV Cameras (GigE) CCD 90 MV Cameras (USB 2.0)

TCP2RTU. Transparentní převodník protokolu MODBUS TCP na MODBUS RTU/ASCII. Tři varianty: pro RS422, RS485 a RS232

2N Lift8 Audio unit machine room

Instalační manuál rev

Spider. Šest 1-Wire senzorů na sběrnici RS-485 CZ

PROGRAMOVATELNÉ AUTOMATY FATEK

2N Voice Alarm Station

User manual SŘHV Online WEB interface for CUSTOMERS June 2017 version 14 VÍTKOVICE STEEL, a.s. vitkovicesteel.com

2N LiftIP. Voice Alarm Station. Communicator for Lifts. Version

Microsoft Lync WEB meeting

1. Automatické řízení osvětlení moderní budovy systémem KNX pomocí protokolu DALI

AS-i ifm electronic Radovan Řeháček AS-Interface

2N Lift8 Splitter. Brief Manual. Version

UPM3 Hybrid Návod na ovládání Čerpadlo UPM3 Hybrid 2-5 Instruction Manual UPM3 Hybrid Circulation Pump 6-9

HWg-STE HWg-STE PoE MANUÁL

Návod k instalaci, provozu a údržbě brány MODBUS. Návod k instalaci, provozu a údržbě. Brána Modbus

COGNEX. DataMan 100. Uživatelská příručka

Synco living. Verze s ECA. Modul pro připojení měřičů spotřeby WRI982. Page 1/15 Michal Bassy - Březen 2011 Březen 2011

LED ROCKDISC II SÉRIE

Sběrnicová stanice BL compact pro CANopen 4 Analog Pt and Ni Sensor Inputs BLCCO-4M12LT-2AI-PT-2AI-PT

Ares 10/12 První spuštění

Uživatelská příručka. Xperia P TV Dock DK21

1. Maple - verze. 2. Maple - prostredi. Document Mode vs. Worksheet Mode

obal manuálu, asi něco podobného jako u LC 100 asi by to chtělo lepší obrázek!!! FYTOSCOPE FS130 Instruction Guide

ADDRESS CONVERSION TABLE FOR MANUAL SETTING

Arduino Ethernet Shield W5100 R3

2. Entity, Architecture, Process

GUIDELINES FOR CONNECTION TO FTP SERVER TO TRANSFER PRINTING DATA

MAXIBUS III hub. SOLARIS Radiový koordinátor

Rozhraní pro připojení požárních ústředen do systému C4

TechoLED H A N D B O O K

Instalace Pokyny pro instalaci v operačním systému Windows XP / Vista / Win7 / Win8

SPECIFICATION FOR ALDER LED

Návod pro připojení telefonu Sony Ericsson P900 jako modem přes datový kabel a pro Windows 2000/XP

NÁVOD K OBSLUZE LAN ovladač s relé


Tento modul by bez problémů měl vyhovovat Vašemu zadání.

spa díly spa components jedineèná relaxace Swimmingpool Technology unique relaxation


Gymnázium, Brno, Slovanské nám. 7 WORKBOOK. Mathematics. Teacher: Student:

Dvojitý IP teploměr s výstupním relé a s digitálním a analogovým vstupem.

Quido - Telnet. Popis konfigurace modulů Quido protokolem Telnet. 3. srpna 2007 w w w. p a p o u c h. c o m

AWZ 520 MP5 v.1.0 RELÉ MODUL/RELAY MODULE CZ/EN

Internet-bridge XPort

WI180C-PB. On-line datový list

DATA SHEET. BC516 PNP Darlington transistor. technický list DISCRETE SEMICONDUCTORS Apr 23. Product specification Supersedes data of 1997 Apr 16

Průvodce rychlým nastavením

Butler. řízení výstupů a měření teploty po ethernetu

GENERAL INFORMATION RUČNÍ POHON MANUAL DRIVE MECHANISM

MAXIMUM DC INPUT CURRENT NO LOAD CURRENT DRAW OVER LOAD / SHORT CIRCUIT OVER TEMPERATURE HIGH DC INPUT VOLTAGE DC INPUT VOLTAGE, VOLTS

Blast Rozhraní DeviceNet

HWg-STE HWg-STE PoE MANUÁL

Postup získání licence programu DesignBuilder v4

čtyři digitální I/O kanály bez bezpečnostní funkce dva konektory IO-Link master V1.1 Obrázek 1 Obrázek 2 Typové označení

1 Instalace HASP Licence Manger pod Windows 7

Router Modbus RTU RS485 / Modbus TCP

Česká verze. Úvod. Pohled zepředu. RO003/RO003UK Sweex širokopásmový router (směrovač)

HCS-3300/3302/3304 USB Dálkově programovatelný laboratorní spínaný napájecí zdroj

Aktion Connector NÁVOD

Megapixelová síťová kamera: PIXORD P606 (2.0 Mpx, H.264, IR)

Mechanika Teplice, výrobní družstvo, závod Děčín TACHOGRAFY. Číslo Servisní Informace Mechanika:

log in AHD_DVR Průvodce rychlým startem První část: základní operace

Obsah. 1. Upozornění. 2. Všeobecný popis

HTemp-485. Teplotní a vlhkostní čidlo pro vnitřní použití na sběrnici RS-485 s jednoduchým komunikačním protokolem CZ

Převodník Ethernet RS232 s Modbus RTU / TCP routerem

UŽIVATELSKÁ PŘÍRUČKA

NAS 323 NAS jako VPN Server

Sběrnicová stanice BL compact pro DeviceNet Interface for Connection of 2 BL ident Read/Write Heads (HF/UHF) BLCDN-2M12S-2RFID-S

Jak resetovat heslo administrátora Rychlý průvodce HIKVISION TECHNICAL SUPPORT TEAM

Novinky u zařízení pro sériovou komunikaci. Michal Kahánek

Předmluva... 2 Popis panelu... 4 Obsah balení... 5 Instalace acces pointu... 5 Inicializace a nastavení acces pointu... 5 Řešení problémů...

Průvodce rychlým nastavením

ATS01N232QN softstartér pro asynchonní motor - ATS01-32 A V - 15 kw

Ethernet převodníky sériových linek. v Přepěťová ochrana 30A AI RE AO DO. minilan-485 AI RE AO DO EZS PIDS EKV. MIOS & Modbus IO moduly nebo senzory

LAN/RS485. Převodník BMR Ethernet LAN/RS485

POPIS TUN TAP. Vysvetlivky: Modre - překlad Cervene - nejasnosti Zelene -poznamky. (Chci si ujasnit o kterem bloku z toho schematu se mluvi.

CON-LAN. Komunikační převodník tf hit <-> Ethernet. Kompletní příručka

P-334U. Bezdrátový Wi-Fi router kompatibilní s normou a/g. Příručka k rychlé instalaci

Obsah. KELOC CS, s.r.o... v ý v o j a p r o d e j e k o n o m i c k é h o s o f t w a re

EtherNet/IP. 5pinové napájení 2x bezpečný digitální vstup

NAPÁJECÍ ZDROJE ČISTÝ VÝKON POWER SUPPLIES PURE POWER PROLUMIA

Nastavení DCOM. Uživatelský manuál

Super Hot Multiplayer vzdálené sledování finančních dat. Konfigurace sítě. Strana: 1 / 8

Upozornění před instalací

TECHNICKÝ MANUÁL. VRF Kit 28 kw. VRF Kit 45 kw SOUPRAVA PRO PŘIPOJENÍ TEPELNÝCH VÝMĚNÍKŮ K SYSTÉMŮM FUJITSU VRF-VII. Pro venkovní jednotky FUJITSU:

technický list PCB MOUNT SOLID STATE RELAY ESR2 SERIES FEATURES PART NUMBERING SYSTEM

Pravým tlačítkem na počítač /tento počítač/ a vybrat Spravovat

Instrukce pro vzdálené připojení do učebny 39d

TCP2RTU. Transparentní převodník protokolu MODBUS TCP Master na MODBUS RTU Slave. Tři varianty: pro RS422, RS485 a RS232

USER'S MANUAL FAN MOTOR DRIVER FMD-01, FMD-03

Transkript:

PC - Controller Central unit with Ethernet interface TECHNICAL MANUAL ACC-NET Applicable for the FUJITSU- GENERAL indoor units of split and multisplit types

DESCRIPTION ACC-RS module for the data collection from ACC-bus with Ethernet interface. The module is equipped with an external inputs and outputs in addition. External outputs Power supply 230 VAC LED indicator of communication BUSY Ethernet RJ-45 port External inputs ACC-bus terminal INSTALLATION 1. Placing: The module is designed for mounting on the DIN rail. IP20 protection enables its location in indoor enviroment or in outdoor distribution box. 2. Power supply: The power supply is 230 VAC/50Hz, the input power is 2W. 3. Communication line: The communication between modules is running on the ACC-bus. Used connecting cable must be the type of shielded twisted pair. Suitable cable is for example the cable of LonWorks specification used for communication VRF-S,V,VII systems. Shielding of individual sections of communication cable must be connected to each other, with grounding in one place on the GND teminal of ACC-RS central unit. 4. Connecting of Ethernet cable: RS-232 cable (in accessory) is used for connection of ACC-RS module to serial COM port of PC. In case of using the extension cable the total connection lenght may be maximum 10 m (in an enviroment without electromagnetic interference). 5. External outputs: Two dry contacts with maximum loading 230 VAC / 2 A. Output Operation is closed if at least one indoor unit is in operation mode. Output Error is closed if at least one indoor unit is failed. 6. External inputs: Contact enable connection of external contacts loaded with current of 10mA at voltage of 12 VDC: - ON All units switch-on ( the operation is triggered by rising edge of pulse) - OFF All units switch-off (the operation is triggered by rising edge of pulse) - AL - Alarm loop. Contact opening generates the Alarm signal in status word of PC-Controller. - BL - Blocking of operation. All units switch-off. During the switching of contact the units can not be switched-on in any way. After the end of pulse the units will remain switched-off and they can be switched-on by any of possible ways.

ACC-NET setting Co budete potřebovat: - PC, který bude sloužit jako server, připojený na Ethernet, vybavený některým z operačních systémů Windows XP, Windows 7, Server 2003, nebo Server 2008. - Na tomto PC vytvořte složku s programy ACCstool.exe, ACCSRV.exe, ACCMNG.exe a I.bat 1. Nastavení síťového rozhraní modulu ACC-NET: - Připojte ACC-NET k síti Ethernet, pokud možno na stejný switch, ke kterému je připojen PC server. - Spusťte program ACCstool.exe (oproti původnímu ACCstool pro ACC-RS obsahuje navíc záložku ACC-NET) a otevřete záložku ACC-NET. -Vyplňte MAC adresu kódem uvadeným na bočním štítku modulu ACC-NET. -Vyplňte požadovanou IP adresu modulu ACC-NET a potvrďte tlačítkem Set NET interface. Proběhlo-li nastavení úspěšně, zbarví se okno IP address zeleně. -Další adresy si program vyplní sám (Server IP, Mask, Server port, Gateway address). -Ukončete program ACCstool.exe Pozn.: V případě, že je číslo UDP portu v okně Server port již obsazeno jinou službou, použijte jiný volný UDP port. POZOR! Při každém použití programu ACCstool je třeba zastavit službu ACCSRV!

2. Instalace služby ACCSRV na PC server Tato služba umožní komunikaci serveru až s 256 moduly ACC-NET, z nichž jeden až dva mohou být nahrazeny moduly ACC-RS2 připojené na COM porty serveru. - Spusťte program I.bat, který nainstaluje službu ACCSRV. -Při prvním spuštění je vytvořen soubor ACCSRVC.log a služba je ukončena. - Soubor ACCSRVC.log obsahuje hlášení, obsahující kód pro generování klíče. Tento kód pošlete svému distributorovi k vygenerování klíče. -Klíč, který obdržíte od svého distributora, vložte do příslušného řádku souboru ACCSRV.ini a soubor uložte. - Spusťte a pak zastavte službu ACCSRV (Tento počítač\správa počítače\služby) -Otevřete soubor ACCSRV.ini a editujte následující parametry: UDPPort použijte číslo portu z ACCstool (v tomto případě 10100). Musí být shodně nastaveno ve všech modulech ACC-NET v rámci jednoho serveru. Ve firewallu PC serveru musí být tento port povolen. čísla použitých COM portů. Není-li zapsáno žádné číslo, COM port není použit. TCPPort program automaticky nastaví port 1025. V případě, že je tento port již obsazen jinou službou, použijte jiný volný TCP port. Ve firewallu PC serveru musí být tento port povolen. Nastavení úrovní logů (jaký rozsah provozních informací se bude zapisovat do souborů.log): ACCSRVS.log unit status log: Level Description 0 no log 1 only on Error or OK status 2 all setting changes(recommended) 3 all 3. Instalace ovládací konzoly ACCMNG: ACCSRVC.log connection log: Level Description 0 no log 1 start/stop service 2 connect/disconnect management console(recommended) - Program ACCMNG.exe zkopírujte na PC, použité pro ovládací konzolu. V rámci jednoho systému ACC může být až 10 těchto konzol. -Spusťte a zastavte ACCMNG.exe -Otevřete vytvořený soubor ACCMNG.ini a editujte: -IP adresu 127.0.0.0 změňte na skutečnou IP adresu serveru -Skutečné číslo TPC portu (1025) -změny uložte a soubor zavřete. -Pro Windows 7 (Server 2008) je nutno program ACCMNG spustit v módu kompatibility s Windows XP SP3. 4. Nastavení modulu ACC-WIRE a drátového ovladače: Modul ACC-WIRE může být připojen k vnitřní jednotce samostatně, nebo v kombinaci s drátovým dálkovým ovladačem. Jsou možné následující kombinace: - Ovladač UTB-YUB nebo UTH-3TA16: - jednotka bez ovladače, modul je třeba nastavit jako Master - jednotka s ovladačem, modul nastavit jako Slave, ovladač jako Master, volbu Dual - Ovladače UTB-YUD, UTY-RNKY: - jednotka bez ovladače, modul nastavit jako Master - jednotka s ovladačem, modul jako Slave (tyto ovladače volbu Dual nemají)

COMMUNICATION CODES ACC PC-Controller communicate with superset control system by ASCII strings through RS-232 line. Setting of serial port: PC Port: COM1 (factory setting, it can be changed in ACCstool.ini file) Setting of COM port: 9600 Baud, Parity:none, Stopbit:1 Data:8bit Structure of command line: xxx,xxx,xxx,xxx,xxx<cr> Description of commands: Acciu - adress setting c - 00..FF controller adress (LL = broadcast Control Unit) i - 0..F interface adress (L = broadcast Interface Port) u - A..D IR codes only by response (it is set in Interface Port) - by WIRE model (A=MASTER B=SLAVE) e.g. A785B, ON switchon OF switchoff Ttt temperature setting tt - 16.. 30 C e.g. T18, Mm mode setting m - ACDFH - A=auto C=cool D=dry F=fan H=heat e.g. MC, Ff fan setting f - AHML - A=auto H=high M=med L=low e.g. FM, Ss swing setting s -FHVB - Dd airflowdirection d - HV - Ee - energy save setting e -FN - RI Reset interface F=off H=horizontal V=vertical B=both H=horizontal V=vertical F=off N=on e.g. SH, e.g. DV, e.g. EN, The commands may be merged, but always they must begin with an adress e.g. A781B,ON,MC,T17 Between the individual command strings (containing one or group of commands) there must be at least 2 s pause. Timer functions are not supported.

STATUS DISPLAY The state informations are periodically sent by the system. The status may be also displayed by the command:? show status The status string have a constant lenght for easier to decode. e.g. A011B,E0003,ON,MC,T26,FM,EF,SF,TA+23,TB.NA,VI01,LSF A011B,E-OK-,OF,MC,T26,FM,EF,SF,TA.NA,TB-03,VW02,LSF The status string also contains those informations: Exxxx - error status xxxx error code -OK- if the unit is O.K. Vtxx -version t interface type I ACC-IR, W ACC-WIRE xx - firmware version LSN (loop secure closed = OK), or LSF (loop secure open = Alarm) TAstt,TBstt temperatures of the external sensors ATS-A and ETS-B If the sensor is not connected, then is displayed.na e.g. TA+22,TB-05, TA.NA,TB+21, Status changes: @A alarm event @E error event @O - status OK restored