HANA OVADOVÁ-NEJEZCHLEBOVÁ a, TOMÁŠ VACULOVIČ b, PAUL EK c, JAN HAVLIŠ d,e a VIKTOR KANICKÝ a,b. Úvod
|
|
- Nikola Marešová
- před 8 lety
- Počet zobrazení:
Transkript
1 KRYOGENICKÁ POSTSEPARAČNÍ ÚPRAVA POLYAKRYLAMIDOVÝCH GELŮ PRO METALOPROTEOMICKÉ ANALÝZY KOMBINACÍ GELOVÉ ELEKTROFORÉZY, LASEROVÉ ABLACE A HMOTNOSTNÍ SPEKTRO- METRIE S IONIZACÍ INDUKČNĚ VÁZANÝM PLAZMATEM HANA OVADOVÁ-NEJEZCHLEBOVÁ a, TOMÁŠ VACULOVIČ b, PAUL EK c, JAN HAVLIŠ d,e a VIKTOR KANICKÝ a,b a Masarykova univerzita, Přírodovědecká fakulta, Ústav chemie, Oddělení analytické chemie, Laboratoř atomové spektrochemie, Brno, b Masarykova univerzita, Středoevropský technologický institut, Centrum nanoa mikrotechnologií, Laboratoř syntézy a analýzy nanostruktur, Brno, c Åbo Akademi University, Laboratory of Analytical Chemistry, Åbo (Turku), Finsko, d Masarykova univerzita, Středoevropský technologický institut, Mendelovo centrum genomiky a proteomiky rostlin, Proteomika CF, Brno, e Masarykova univerzita, Přírodovědecká fakulta, Ústav experimentální biologie, Oddělení funkční genomiky a proteomiky, Centrální laboratoř, Brno jdqh@sci.muni.cz Došlo , přijato Rukopis byl zařazen k tisku v rámci placené služby urychleného publikování. Klíčová slova: gelová elektroforéza, laserová ablace, indukčně vázané plazma, hmotnostní spektrometrie, metaloprotein, kov vázající protein, ablační, celofánová fólie, sušení gelu Úvod Přibližně třetina všech biogenních proteinů obsahuje vázanou kovovou specii 1. Obecně dělíme proteiny obsahující kovové specie na metaloproteiny (metalloproteins; kovová specie je integrální součástí struktury proteinu) a kov vázající (metaloligentní) proteiny (metal-binding proteins; kovová specie není integrální součástí struktury proteinu). Proteiny obou těchto tříd se pak skládají z (apo) proteinu (výraz apoprotein zde má smysl jen u metaloproteinů) a kovové specie 2. Kovové specie vázané na proteiny hrají různé esenciální role v organismech (biokatalytické, strukturní, vazebné a depozitní/transportní), mohou však způsobovat i toxicitu 3. Takže úplná informace o proteinech obsahujících kovovou specii, tj. identita (apo)proteinu a speciace kovového prvku, umožňuje studovat jejich role v metabolismu (esencialita i toxicita). Proteiny interagují slabě s ionty prvků 1. skupiny (sodík, draslík), silněji s ionty prvků 2. skupiny (vápník, hořčík). Na druhé straně, např. přechodové kovy mají díky svému malému atomovému poloměru a interakcím skrze elektromagnetické a elektrostatické síly silné koordinační vazby 2 ; k nim patří i ionty zinku a kobaltu, zahrnuté v této studii. Kobalt se často v kontextu metaloproteinů vyskytuje v souvislosti s výskytem zinku, i když na rozdíl od zinku, kobalt hraje v biologických systémech méně endogenních rolí 1,4. Specie kobaltu se mohou vázat do stejných vazných míst jako specie zinku 5, výpočetní interakční studie ale poukazují na rozdílné vazné vlastnosti kobaltu a zinku v metaloproteinech 6. Metalomice (analýze souborů kovových specií v organismech) a metaloproteomice (podoboru metalomiky, zabývajícího se soubory metaloproteinů a mataloligentních proteinů) byla a je pro jejich význam věnována značná pozornost 7. Hlavním zobecněním dosavadních studií je tzv. metalomický analytický přístup (MAA; metallomics analytical approach) popsaný v práci 3, shrnující základní analytický postup sestávající se ze tří hlavních komponent: selektivitní komponenta separační technika (např. SDS-PAGE, CE, HPLC), citlivostní komponenta prvkově vysoce citlivý detektor (např. XRF nebo ICP MS), strukturní komponenta molekulově specifický detektor (např. MS). Separační komponentu lze prakticky realizovat buď v on-line spojení separační techniky (LC, gelové elektroforézy (GE) 8 nebo CZE) s citlivostní komponentou (ICP- AES nebo ICP-MS) nebo off-line spojením obou komponent, např. detekcí metaloproteinů ve frakcích po chromatografické separaci či separaci plošnou GE 9. Separace pomocí GE je stále považována za jednu z nejúčinnějších metod separace (metalo)proteinů spolu s identifikací kovové specie pomocí PIXE 10 nebo ICP- MS 7. S postupy uplatňujícími ICP-MS úzce souvisí postseparační úpravy gelů (převážně polyakrylamidových). Spojení GE a ICP-MS se nejčastěji realizuje prostřednictvím laserové ablace (LA) materiálu gelu a separovaných metaloproteinů s následnou atomizací a ionizací v ICP 11 ; alternativou je rozklad gelu a následná přímá analýza prvkových specií 12. Poněvadž elektroforetický gel obsahuje vysoké procento vody (~ 90 %), jejíž odpařování způsobuje deformace a trhání gelu při ablaci, musíme snížit obsah vody v gelu. Děje se tak buď sušením (např. bez dalších úprav v sušičce gelů 13 nebo mezi 14 ) nebo nahrazením vody vhodnou kapalinou (např. glycerolem) 14. Proces sušení musí nejenom zajistit geometrické vlastnosti gelu (planaritu), ale i fyzikálně-chemické (obsah vody), a také intaktnost separovaných proteinů. Úspěšnou studií aplikující kombinaci GE-LA-ICP-MS (GLIM) je práce Becker a spol. 13 zahrnující analýzu sérového albuminu s vázanými ionty Cu 2+ a Zn
2 Jako alternativa k ablaci gelů, a tudíž eliminaci kroku sušení, může posloužit přenos otisku gelu na membránu (blotting) a následná ablace otisku. Tento postup přináší riziko uvolnění vázané kovové specie; s úspěchem byl proto zatím použit jen pro proteiny obsahující kovalentně vázané heteroatomy; selenoproteiny 15 a fosfoproteiny 16. Dalším, hypoteticky možným, postupem pro ablaci elektroforetických gelů v procesu GLIM je využití ablace v kryogenické cele. Tento postup byl poprvé pro analýzu kovových specií v biologickém materiálu použit v práci Ek a spol. 17. Využití kryogenické cely minimalizuje odpařování vody při ablaci a zaručilo by tak integritu gelu. Navíc, díky toku inertního plynu celou by proces zmrazení gelu byl zároveň doprovázen částečným vysoušením. V této studii se zaměřujeme na využití laserové ablace v kryogenické cele jako techniky paralelní k jiným postseparačním postupům v procesu analýzy metaloproteinů dělených pomocí plošné gelové elektroforézy s detekcí kovových specií hmotnostní spektrometrií s ionizací indukčně vázaným plazmatem. Naším cílem je poukázat na možnosti využití laserové ablace polyakrylamidových gelů v tomto procesu. Studie byla provedena s modelovým metaloproteinem alkoholdehydrogenasou (ADH), obsahujícím specie zinku, a modelovým kov vázajícím proteinem hovězím sérovým albuminem (BSA) s vázanými ionty Co 2+. Experimentální část Reagencie Pro přípravu polyakrylamidových (PA) gelů byl použit akrylamid (30% v/v) a bis-akrylamid (37,5:1 v/v), dodecylsíran sodný (SDS), 1,2-bis(dimethylaminoethan (TEMED), tris(hydroxymethyl)aminomethan (Tris) (vše Bio-Rad, Philadelphia, USA). Methylenová modř (Lachema, Brno) byla použita jako vodící barvivo pro separaci proteinů pomocí nedenaturující PAGE, bromofenolová modř (Lachema, Brno) pak jako vodící barvivo pro separaci proteinů v denaturující PAGE. Methanol, thiosíran sodný, dusičnan stříbrný, heptahydrát síranu zinečnatého, hydrogenuhličitan sodný a formaldehyd (čistý) byly od fy Lachema (Brno, ČR), hexahydrát chloridu kobaltnatého od fy Merck (Darmstadt, SRN). ADH (obsahující Zn 2+ ), BSA, peroxosíran amonný (APS) a glycin byly od fy Sigma-Aldrich (Steinheim, SRN). BSA-Co 2+ 1:1 byl pak připraven rozpuštěním přesně naváženého BSA v ekvimolárním roztoku iontů Co 2+ (10 4 mol dm 3 ). Elektroforetický Lämmliho vzorkovací pufr pro denaturující PAGE, merkaptoethanol a celofánová fólie byly od fy Bio-Rad, a glycerol od fy Vitrum Rožnov s.r.o., (Rožnov pod Radhoštěm). Modř Coomassie Brilliant R-250 (CBB R-250) byla od fy Serva (Heidelberg, SRN). Kapalný dusík (Linde Gas, Brno) byl použit pro chlazení kryogenické ablační cely. Všechny experimenty byly konány s dvojnásobně destilovanou vodou z křemenného aparátu Hereaeus Bi-8 (Heraeus Quarzglass, GmbH&Co. KG, Kleinheim, SRN). Aparatura Vertikální gelová elektroforéza ve verzi mini byla prováděna na zařízení Mini-Protean 3 Cell doplněném zdrojem PowerPacBasic TM (Bio-Rad), rozměry gelů byly 7,3 cm 10,2 cm. Jako sušička gelů bylo použito zařízení GD5040 (Scie-Plas, Cambridge, Velká Británie). Pro stanovení kovových specií byl použit spektrometer ICP-MS Agilent 7500ce (Agilent Technologies, Palo Alto, USA) vybavený oktapólovou reakční celou a laserovým ablačním systémem UP213 (ESI New Wave Research, Fremont, USA) s laserem Nd:YAG operujícím na vlnové délce 213 nm. Laserová ablace byla prováděna v kryogenické cele vlastní výroby (Laboratory of Analytical Chemistry, Åbo Akademi University, Åbo, Finsko) a bez vymrazování v ablační cele Supercell (ESI New Wave Research). Podmínky LA-ICP-MS Pro ablaci gelu byl použit laser Nd:YAG buzený xenonovou výbojkou, emitující záření o vlnové délce 213 nm (pátá harmonická frekvence) s délkou pulzu 4 ns. Energie laserového záření byla nastavena na hodnotu cca 3 mj. Procento maximálního výkonu xenonové výbojky bylo nastaveno podle výsledků optimalizace a tomu odpovídající hustota zářivého výkonu laserového záření byla měřena v průběhu ablace, protože tato hodnota v průběhu času kolísá. Gely s metaloproteiny byly ablatovány ve směru separace. Ablatovaný materiál byl potom transportován proudem hélia do indukčně vázaného plazmatu. Ionty vytvořené v ICP byly extrahovány do hmotnostního spektrometru a separovány podle jejich efektivní hmotnosti (m/z) v kvadrupólovém hmotnostním analyzátoru. Pracovní podmínky laseru a ICP-MS jsou shrnuty v tab. I. Detegovány a měřeny byly izotopy 59 Co, 13 C, 66 Zn. Intenzita signálu (iontočet) těchto izotopů byla sledována při průtoku nosného plynu (He) 1 dm 3 min 1. Intenzita signálu izotopu 13 C byla použita na korelaci fluktuací výkonu xenonové výbojky (normalizace intenzity signálu), neboť jeho obsah se v gelu pokládá za rovnoměrný oproti iontům měřených kovových specií. Výsledná normalizovaná hodnota intenzity signálu je poměrem intenzity signálu izotopu analyzované specie kovu a izotopu 13 C. Tabulka I Podmínky měření. Systém pro laserovou ablaci Nd:YAG laser UP 213 0,6 Parametr Hodnota Hustota zářivého výkonu, GW cm 2 ~0,5 Vlnová délka, nm 213 Opakovací frekvence, Hz 20 Rychlost skenování, m s 1 50 Rychlost toku nosného plynu, He, dm 3 min 1 1 Rychlost toku pomocného plynu, Ar, dm 3 min 1 897
3 Jak v případě ablace v kryogenické cele, tak i v případě ablace sušených gelů bylo třeba vyřezat z gelu část separační stopy, obsahující separační zóny proteinů, a ty umístit horizontálně na Z-stojan ablační cely. Rozměry těchto částí byly cca 2,5 4,5 cm (šířka výška). V případě kryogenické ablace není potřeba žádných adhezivních materiálů, gel přimrzne ke skleněné podložce, jež zapadá do manipulační pohyblivé plochy Z-stojanu cely. V případě ablace sušených gelů byly tyto mechanicky upevněny páskou. Podmínky separace gelovou elektroforézou Metaloproteiny byly po nadávkování prekoncentrovány izotachoforézou v koncentračním segmentu diskontinuálního gelu (4% zesítění) po dobu 10 min při stálém napětí 100 V a po té separovány v separačním segmentu gelu (12% zesítění) podle jejich molekulové hmotnosti pomocí 1D polyakrylamidové gelové elektroforézy (PAGE) v denaturačním (SDS) modu podle Laemmliho 18 nebo podle velikosti a náboje pomocí polyakrylamidové gelové elektroforézy v nedenaturačním (SDS) modu s využitím protokolu Ornsteina 19 a Davise 20. Separace v obou případech trvala 40 min s konstantním napětím 200 V. Vizualizace proteinů v gelech Polyakrylamidové gely byly barveny stříbrným ionty 21 a skladovány v 1% kyselině octové při 4 C, nebo modří CBB R a také skladovány při 4 C. V případě potřeby byly gely barvené modří CBB R-250 odbarvovány roztokem 5% methanolu a 7,5% kyseliny octové. Postseparační úpravy gelů pro laserovou ablaci Abychom předešli nežádoucí deformaci gelů při ablaci (uvolňování plynné vody a z toho plynoucí ztráta planarity a trhání), polyakrylamidové gely musí před ablací projít úpravou. Studovali jsme chování systému GLIM s kryogenickým vymražením gelu ve srovnání s klasickými postupy (prosté sušení a sušení mezi ). Hlavními hledisky byla identifikace přítomnosti kovové specie pocházející z proteinu obsahujícího kov v jeho separační zóně. Kryogenické vymražení Nebarvené gely byly skladovány ve fixačním roztoku (45% methanol, 2% kyselina octová) při 4 C, gely barvené stříbrnými ionty byly skladovány v roztoku 1% kyseliny octové a modří CBB v roztoku 5% methanolu a 7,5% kyseliny octové při 4 C. Prosté sušení v sušičce gelů Gel na filtračním papíru byl vložen na desku sušičky gelů a poté byl pokryt membránou z polyvinyliden chloridu (PVDC). Teplota sušení byla 40 C. Sušení mezi Gel a dvě celofánové fólie byly ponořeny do 2% roztoku glycerolu na dvě hodiny při 4 C. Poté byl gel vložen mezi obě fólie, spodní fólie spočívala na skleněné desce a okraje horní přesahovaly rozměr gelu. Okraje obou fólií byly zarovnány a po odstranění bublin vzduchu byl gel sušen ve tmě. Po minimálně dvou až třech dnech byl gel v celofánové folii odstraněn ze sklíčka a přesahující okraje fólie zastřihnuty. Výsledky a diskuse Optimalizace procesu GLIM Optimalizace spočívala v nalezení podmínek získání maximální intenzity signálu v MS a její minimální RSD. Další podmínkou optimalizace byla rovnoměrná tvorba kráterů. Podle předběžných experimentů tyto parametry závisí na hustotě zářivého výkonu laseru, typu barvení a způsobu úpravy gelu. Optimalizace základních parametrů probíhala se všemi třemi způsoby úpravy gelu na polyakrylamidových gelech se zesítěním 12 %, které byly saturované roztokem Co 2+ či Zn 2+ (10 4 mol dm 3 ). Obecně, ablace a záznamy signálu ICP-MS byly dělány ve třech opakováních na třech různých místech gelu za stejných experimentálních podmínek. Výsledné sady dat posloužily k výpočtu průměrných hodnot intenzit signálu a jejich RSD pro jednotlivé sady. Z nich byly následně vypočítány hodnoty sdružených průměrů, standardních a relativních standardních odchylek nepřekrývajících se sad dat. Vliv úpravy gelu na hodnotu intenzity signálu a její RSD Výsledky jsou shrnuty v tab. II a III. Údaje v nich obsažené vymezují použitelné rozsahy hustot zářivého výkonu pro efektivní ablaci gelů po úpravě. Vliv barvení gelu na hodnotu intenzity signálu a její RSD Separační zóny metaloproteinů v elektroforetogramech po denaturační PAGE byly vizualizovány stříbrem nebo modří CBB R-250. Poté byly upraveny pro laserovou ablaci (prosté sušení, sušení mezi, kryogenické vymražení). Ablace byla prováděna v místě separační zóny. Výsledky ukazují, že ablace stříbrnými ionty barvených gelů vykazují vyšší hodnoty intenzity signálu (až dvojnásobně) a nižší RSD (až o dvě třetiny) než ablace gelů barvených modří CBB. Proto bylo barvení stříbrnými ionty výhradně použito v dalších experimentech. Vliv rozměru ablačního kráteru a rychlosti skenování gelu na hodnotu intenzity signálu a její RSD Velikost ablačního kráteru byla dalším optimalizovaným parametrem vzhledem k zahlcení ICP-MS ablatovaným materiálem. Volilo se mezi mezními poloměry 15 m a 100 m v souladu s předběžnými experimenty a z nich plynoucím výhledem na hodnoty intenzity signálu ICP-MS a její RSD. Nejnižší poloměr kráteru neposkytoval téměř žádný měřitelný signál, v druhém případě byl signál o čtyři řády vyšší než pozadí. Aby byla účinnost ablace maximální, byla nadále používána průměrná velikost ablačního kráte- 898
4 Tabulka II Vliv hustoty zářivého výkonu na intenzitu signálu v ICP-MS a její sdružené RSD při detekci 59 Co 2+ Hustota zářivého výkonu [GW cm 2 ] Normalizovaná intenzita signálu 59 Co/ 13 C Sdružená RSD [%] 0,02 2,35 0,35 0, ,03 3,89 1,74 0, ,13 1,69 6,30 2, ,50 3,43 8,52 4, ,03 9,55 10,4 8, ,61 10,0 10,6 15, ,31 11,1 10,5 29, ,90 11,9 10,4 41, ,49 16,3 9,67 46, Tabulka III Vliv hustoty zářivého výkonu na intenzitu signálu v ICP-MS a její sdružené RSD při detekci 66 Zn 2+ Hustota zářivého výkonu [GW cm 2 ] Normalizovaná intenzita signálu 66 Zn/ 13 C Sdružená RSD [%] 0,02 3,05 0,02 3, ,03 6,30 0,11 3, ,44 6,60 0,20 3, ,84 4,37 0,23 2, ,57 5,71 0,32 3, ,24 4,20 0,29 2, ,15 4,84 0,49 3, ,85 4,45 0,48 2, ,43 4,88 0,17 3, ru 100 m. Rychlost ablačního skenování hodnoty intenzity signálu neovlivnila, takže ta byla volena jen na základě požadovaného laterálního rozlišení, a sice 50 m s 1. Vliv teploty v kryogenické cele a doby vymrazování na intenzitu signálu v ICP-MS a její RSD Hodnoty teplot volené pro tyto experimenty byly 50 C; 60 C; 70 C a 80 C a časy 0 až 70 min. Experimenty probíhaly jinak za podmínek, které vyplynuly z minulých experimentů. Nejvyšší intenzity signálů byly dosaženy při 80 C a po 25 min vymrazování při této teplotě. Tyto podmínky pak byly použity v dalších experimentech při ablaci v kryogenické cele. Srovnání intenzit signálů po laserové ablaci gelů podrobených různým procedurám úpravy po separaci v denaturačním a nedenaturujícím módu PAGE Vliv použití kryogenické cely oproti klasickým způsobům úpravy gelů byl zkoumán při laserové ablaci metaloproteinů separovaných PAGE. V prvním případě šlo o gely obsahující BSA-Co 2+ 1:1 o koncentraci 10 4 mol dm 3 separované v denaturujícím módu. Jedna sada gelů byla barvena stříbrem a druhá nebarvena. Při ablaci v normální ablační cele byla použita hustota zářivého výkonu 0,13 GW cm 2, v kryogenické cele 2,30 GW cm 2. Při barvení stříbrem ablace sušených gelů ve standardní cele poskytovala vyšší intenzitu signálu 899
5 než ablace v kryogenické cele. Situace je naproti tomu opačná při ablaci nebarvených gelů (nedokumentováno). Při separaci v nedenaturujícím módu poskytovaly u barvených gelů nejvyšší intenzity signálů v ICP-MS ablace gelů sušených mezi. V případě ablace nebarvených gelů po nativní PAGE v kryogenické cele byly hodnoty intenzit signálů opět vyšší než u gelů sušených (nedokumentováno). V případě separace ADH s obsahem zinečnatých iontů 10 4 mol dm 3 separované v denaturujícím módu. Opět byla jedna sada gelů barvena stříbrem, a druhá nebarvena. Pro ablaci v normální ablační cele byla použita hustota zářivého výkonu 0,43 GW cm 2, v kryogenické cele 3,15 GW cm 2. Při barvení stříbrem ablace gelů pro všechny tři způsoby úpravy poskytovala přibližně stejné intenzity signálu, v případě sušení mezi byly nejnižší. Při ablaci nebarvených gelů byly intenzity signálů při ablaci vymražených gelů až pětkrát vyšší než pro zbylé dva způsoby úpravy (nedokumentováno). Při ablaci gelů po nedenaturující separaci poskytovaly u barvených gelů nejvyšší intenzity signálů v ICP-MS ablace vymražených gelů (třikrát vyšší než u gelů sušených v sušičce gelů a až desetkrát vyšší než u gelů sušených mezi ). V případě ablace nebarvených gelů po nativní PAGE v kryogenické cele byly hodnoty intenzit signálů asi dvakrát vyšší než u gelů sušených, nicméně absolutní hodnoty signálů byly nízké ve všech třech případech (nedokumentováno). Závěr Úprava gelů před laserovou ablací ve spojení s ICP- MS v procesu GLIM je jednou z nejdůležitějších fází procedury. Gely sušené jen v sušičce neschly rovnoměrně, což činilo manipulaci s gelem, včetně ablace, obtížnou a méně účinnou. Čas přípravy byl dlouhý (1 týden), gely měly tendenci se lámat a trhat i v průběhu ablace. Intenzity signálů v ICP-MS byly pro tuto úpravu za všech podmínek vysoké, ale jejich sdružené RSD také, v případě barvených gelů byly hodnoty RSD relativně nejnižší. To vše činí tento postup nepraktickým. Doba sušení gelů mezi je podstatně kratší (cca 3 dny), ale toto provedení je manuálně náročné. Gel je po vysušení mechanicky homogenní a lze jej snadno skladovat. Intenzity signálů v ICP-MS byly pro tuto úpravu srovnatelné s gely sušenými v sušičce. Výjimkou byly ablace barvených gelů s BSA-Co 2+ 1:1, kde byly intenzity nejvyšší a s nejnižšími RSD. Sdružené RSD byly obecně pro tuto metodu sušení nižší než při sušení v sušičce, viz tab. II a III. Jedinou nevýhodou tohoto způsobu úpravy gelu je potřeba ablatovat nejprve vrstvu celofánu, což může negativně ovlivnit výsledek při nevhodném provedení. Hlavní výhodou ablace vymražených gelů je minimální časová ztráta při úpravě gelu. Po obarvení může být gel skladován při 4 C ve fixačním roztoku nebo rovnou zpracován. Před ablací, aby se zabránilo zamlžení kamery laseru kondenzací odpařené vody, je třeba ablační celu čistit tokem inertního pomocného plynu, nejlépe argonu. Intenzity signálu měřené ICP-MS obdržené po ablaci gelu vymrazovaného po 25 min při 80 C ukazují jiné chování než u ostatních způsobů sušení. Zpočátku jsou hodnoty intenzit nízké a růst začnou až při dosažení hustoty zářivého výkonu 2,3 GW cm 2. Hodnoty RSD těchto intenzit, zpočátku velmi vysoké, výrazně klesají se stoupajícím výkonem laseru. Spotřeba kapalného dusíku pro chlazení ablační cely a možné zanesení vodících cest kondenzujícím materiálem jsou hlavními nevýhodami GLIM vymražených gelů. Kritéria intenzit signálu a doby úpravy gelu jsou však rozhodující pro kvalitu získaných dat. Ablace v kryogenické cele poskytují ať už srovnatelné nebo vyšší intenzity signálů, s výjimkou ablace barvených gelů, kde jsou tyto hodnoty většinou nižší než u ablací gelů upravených sušením. V neposlední řadě výhodou kryogenické ablace může být to, že gel de facto nebyl suchý a je možné s ním poté opět nakládat jako s gelem, kdežto gely sušené kterýmkoliv z obou jiných postupů jsou po ablaci již nepoužitelné. V rámci ověření účinnosti ablace v kryogenické cele byly také ověřeny jiné předpoklady této účinnosti. Za prvé, neboť hlavním cílem separace pomocí PAGE je také udržet kovovou specii vázanou na protein, v literatuře se často setkáme s názorem, že nedenaturující, tzv. nativní PAGE je vhodnější metodou, než denaturující, tzv. SDS PAGE 14. Nicméně se můžeme při analýze metaloproteinů ablací setkat s úspěšným použitím všech typů separace SDS PAGE 22, PAGE se sníženým obsahem SDS 23 a samozřejmě s nativní PAGE 24. Naše výsledky ukazují, že ablace gelů po separaci ADH i BSA-Co 2+ v SDS modu poskytuje vysoké intenzity signálů nehledě na způsob úpravy gelu, viz srovnání obr. 1 a 5. Obr. 1. Záznam závislosti normalizované intenzity signálu 66 Zn 2+ na délkové souřadnici rozměru separační stopy získaný kryogenickou ablací části gelu obsahujícího stříbrem barvenou separační zónu ADH po separaci v denaturujícím módu PAGE 900
6 Obr. 2. Záznam závislosti normalizované intenzity signálu 66 Zn 2+ na délkové souřadnici rozměru separační stopy získaný ablací části gelu sušeného v sušičce gelů obsahujícího stříbrem barvenou separační zónu ADH po separaci v denaturujícím módu PAGE Obr. 4. Záznam závislosti normalizované intenzity signálu 59 Co 2+ na délkové souřadnici rozměru separační stopy získaný ablací části gelu sušeného v sušičce gelů obsahujícího stříbrem barvenou separační zónu BSA:Co 2+ 1:1 po separaci v denaturujícím módu PAGE Obr. 3. Záznam závislosti normalizované intenzity signálu 59 Co 2+ na délkové souřadnici rozměru separační stopy získaný kryogenickou ablací části gelu obsahujícího stříbrem barvenou separační zónu BSA:Co 2+ 1:1 po separaci v denaturujícím módu PAGE Obr. 5. Záznam závislosti normalizované intenzity signálu 66 Zn 2+ na délkové souřadnici rozměru separační stopy získaný kryogenickou ablací části gelu obsahujícího stříbrem barvenou separační zónu ADH po separaci v nedenaturujícím módu PAGE Dalším diskutovaným tématem je vliv vizualizace proteinů gelu jejich barvením na proces GLIM, neboť se předpokládá, že při něm dochází k narušení vazby kovové specie na protein 14,25. Literatura uvádí úspěšné použití barvení gelů stříbrnými ionty pro GLIM 22,26, což naše výsledky potvrzují, viz srovnání obr. 1 s 2, a 3 s 4. Naopak barvení CBB R-250 se ukázalo v našich experimentech jako nevhodné, neposkytující při GLIM žádný měřitelný signál kovové specie, ačkoliv v literatuře existují doloženy případy úspěšného použití 27. Ablace v kryogenické cele je tedy vhodnou alternativou k tradičně používaným metodám úpravy gelů v procesu GLIM (sušení). Na jedné straně vyžaduje speciální ablační celu, chlazenou kapalným dusíkem, na té druhé ale výrazně zkracuje dobu úpravy gelu z řádově dnů na desítky minut při zachování výstupních parametrů ablace, tj. vysoké intenzity signálu měřených iontů a jejich nízké RSD, a umožňuje znovupoužití gelů po ablaci, kupř. pro identifikaci proteinové složky metaloproteinu pomocí hmotnostní spektrometrie. 901
7 Tato práce byla realizována s finanční podporou Grantové agentury České republiky GA203/07/1391 a Ministerstva školství, mládeže a tělovýchovy České republiky MSM , MSM a MSM LITERATURA 1. Shi W., Chance M. R.: Curr. Opin. Chem. Biol.15, 144 (2011). 2. Garcia J. S., Schmidt de Magalhães C., Arruda M. A. Z.: Talanta 69, 1 (2006). 3. López-Barea J., Gómez-Ariza J. L.: Proteomics 6, S51 (2006). 4. Cvetkovic A., Menon A. L., Thorgersen M. P., Scott J. W.,Poole II F. L., Jenney Jr. F. E., Lancaster W. A., Praissman J. L., Shanmukh S., Vaccaro B. J., Trauger S. A., Kalisiak E., Apon J. V., Siuzdak G., Yannone S. M., Tainer J. A., Adams M. W. W.: Nature 466, 779 (2010). 5. Sénèque O., Latour J.-M.: J. Am. Chem. Soc. 132, (2010). 6. Seebeck B., Reulecke I., Kämper A., Rarey M.: Proteins 71, 1237 (2008). 7. Da Silva M. A., Sussulini A., Arruda M. A.: Expert Rev. Proteomics 7, 387 (2010). 8. Brüchert W., Krüger R., Tholey A., Montes-Bayón M., Bettmer J.: Electrophoresis 29, 1451 (2008). 9. Gao Y., Chen Ch., Chai Z.:J. Anal. At. Spectrom. 22, 856 (2007). 10. Szokefalvi-Nagy Z., Kocsonya A., Kovács I., Hopff D., Lüthje S., Niecke M.: Nucl. Instrum. Methods Phys. Res., Sect. B 267, 2163 (2009). 11. Becker J. S., Zoriy M., Krause-Buchholz U., Becker J. S., Pickhardt C., Przybylski M., Pompe W., Rödel G.: J. Anal. At. Spectrom. 19, 1236 (2004). 12. Chéry C. C., Chassaigne H., Verbeeck L., Cornelis R., Vanhaecke F., Moens L.: J. Anal. At. Spectrom. 17, 576 (2002). 13. Becker J. S., Pozebon D., Dressler V. L., Lobinski R., Becker J. S.: J. Anal. At. Spectrom. 23, 1076 (2008). 14. Raab A., Pioselli B., Munro C., Thomas-Oates J., Feldmann J.: Electrophoresis 30, 303 (2009). 15. Ballihaut G., Kilpatrick L. E., Kilpatrick E. L., Davis W. C.: J. Anal. At. Spectrom. 26, 383 (2011). 16. Venkatachalam A., Koehler C. U., Feldmann I., Lampen P., Manz A., Roos P. H., Jakubowski N.: J. Anal. At. Spectrom. 22, 1023 (2007). 17. Feldmann J., Kindness A., Ek P.: J. Anal. At. Spectrom.17, 813 (2002). 18. Laemmli U. K.: Nature 227, 680 (1970). 19. Orstein L.: Ann. N.Y. Acad. Sci.121, 321 (1964). 20. Davis B. J.: Ann. N.Y. Acad. Sci.121, 404 (1964). 21. Shevchenko A., Wilm M., Vorm O., Mann M.: Anal. Chem. 68, 850 (1996). 22. Becker J. S., Zoriy M., Przybylski M., Becker J. S.: Int. J. Mass Spectrom. 261, 68 (2007). 23. Lustig S., Lampaert D., De Cremer K., De Kimpe J., Cornelis R., Schramel P.: J. Anal. At. Spectrom. 14, 1357 (1999). 24. Binet M. R. B., Ma R., McLeod C. W., Poole R. K.: Anal. Biochem. 318, 30 (2003). 25. Jiménez M. S., Rodriguez L., Gomez M. T., Castillo J. R.: Talanta 81, 241 (2010). 26. Becker J. S., Zoriy M., Becker J. S., Pickhardt C., Damoc E., Juhacz G., Palkovits M., Przybylski M.: Anal. Chem. 77, 5851 (2005). 27. Deitrich C. L., Braukmann S., Raab A., Munro C., Pioselli B., Krupp E. M., Thomas-Oates J. E., Feldmann J.: Anal. Bioanal. Chem. 397, 3515 (2010). H. Ovadová-Nejezchlebová a, T. Vaculovič a, P. Ek c, J. Havliš c,d, and V. Kanický a ( a Masaryk University, Faculty of Science, Department of Chemistry, Divisionof Analytical Chemistry, Laboratory of Atomic Spectrochemistry, Brno, b Masaryk University, Central-European Institute of Technology, Centre for Nanotechnology and Microtechnology, Laboratory for Synthesis and Analysis of Nanostructures, Brno, c Åbo Akademi University, Laboratory of Analytical Chemistry, Åbo (Turku), Finland, d Masaryk University, Central-European Institute of Technology, Mendel Centre for Plant Genomics and Proteomics, Proteomics CF, Brno, e Masaryk University, Faculty of Science, Department of Experimental Biologiy, Division of Functional Genomics and Proteomics, Central Laboratory, Brno): Cryogenic Postseparation Treatment of Acrylamide Gels for Metaloproteomic Analyses by Combination of Gel Electrophoresis, Laser Ablation and Inductively Coupled Plasma Mass Spectrometry Analysis of metal species in cryogenic frozen gels originated in polyacrylamide gel electrophoresis (PAGE) by laser ablation (LA) connected to inductively coupled plasma mass spectrometry (ICP-MS) GLIM in abbreviation has been investigated to detect/quantitate them in separated metalloproteins. It was compared to traditional ways of gel drying procedures prior to ablation (plain drying, drying gel sandwiched between two cellophane foils), which are necessary operations before laser ablation to prevent undesired interferences related to gas production during laser ablation because of liquid content. Laser ablation of the gels containing BSA:Co(II) 1:1 and ADH with Zn(II) in cryogenic ablation cell (at 80 C for 25 min) is a relevant alternative to the traditional procedures because of significant time spared during the procedure (down to tens of hours instead of days), it yields comparable outcome of metal species analysis by means of their high signal intensities and low RSD in ICP-MS and because of reusability of gels after cryogenic ablation, e.g. for mass spectrometry driven identification of protein moiety of metalloprotein. 902
IDENTIFIKACE METALOPROTEINŮ A STANOVENÍ JIM PŘÍSLUŠNÝCH KOVOVÝCH SPECIÍ. Hana Ovadová, Tomáš Vaculovič, Viktor Kanický, Jan Havliš
IDENTIFIKACE METALOPROTEINŮ A STANOVENÍ JIM PŘÍSLUŠNÝCH KOVOVÝCH SPECIÍ Hana Ovadová, Tomáš Vaculovič, Viktor Kanický, Jan Havliš Katedra analytické chemie, Přírodovědecká fakulta, Masarykova Univerzita
LASEROVÁ ABLACE S HMOTNOSTNÍ SPEKTROMETRIÍ V INDUKČNĚ VÁZANÉM PLAZMATU PRO 2D MAPOVÁNÍ MOČOVÝCH KAMENŮ
Chem. Listy 13, s193 s197 (29) Cena Merck 29 LASEROVÁ ABLACE S HMOTNOSTNÍ SPEKTROMETRIÍ V INDUKČNĚ VÁZANÉM PLAZMATU PRO 2D MAPOVÁNÍ MOČOVÝCH KAMENŮ MONIKA NOVÁČKOVÁ, MARKÉTA HOLÁ a VIKTOR KANICKÝ Oddělení
Evropský sociální fond Praha & EU: Investujeme do vaší budoucnosti ELEKTROMIGRAČNÍ METODY
Evropský sociální fond Praha & EU: Investujeme do vaší budoucnosti ELEKTROMIGRAČNÍ METODY ELEKTROFORÉZA K čemu to je? kritérium čistoty preparátu stanovení molekulové hmotnosti makromolekul stanovení izoelektrického
SDS polyakrylamidová gelová elektroforéza (SDS PAGE)
SDS polyakrylamidová gelová elektroforéza (SDS PAGE) Princip SDS polyakrylamidová gelová elektroforéza slouží k separaci proteinů na základě jejich velikosti (molekulové hmotnosti). Zahřátím vzorku za
Hmotnostní spektrometrie
Hmotnostní spektrometrie Princip: 1. Ze vzorku jsou tvořeny ionty na úrovni molekul, nebo jejich zlomků (fragmentů), nebo až volných atomů dodáváním energie, např. uvolnění atomů ze vzorku nebo přímo rozštěpení
Obsah Protein Gel Electrophoresis Kitu a jeho skladování
Obsah Protein Gel Electrophoresis Kitu a jeho skladování Protein Gel Electrophoresis Kit obsahuje veškerý potřebný materiál provádění vertikální polyakrilamidové gelové elektroforézy. Experiment provádějí
ANORGANICKÁ HMOTNOSTNÍ SPEKTROMETRIE
ANORGANICKÁ HMOTNOSTNÍ SPEKTROMETRIE (c) David MILDE 2003-2010 Metody anorganické MS ICP-MS hmotnostní spektrometrie s indukčně vázaným plazmatem, GD-MS spojení doutnavého výboje s MS, SIMS hmotnostní
HMOTNOSTNÍ SPEKTROMETRIE - kvalitativní i kvantitativní detekce v GC a LC - pyrolýzní hmotnostní spektrometrie - analýza polutantů v životním
HMOTNOSTNÍ SPEKTROMETRIE - kvalitativní i kvantitativní detekce v GC a LC - pyrolýzní hmotnostní spektrometrie - analýza polutantů v životním prostředí - farmakokinetické studie - kvantifikace proteinů
KVANTITATIVNÍ ANALÝZA SPECIÍ JODU V BIOLOGICKÝCH VZORCÍCH SPOJENÍM VYLUČOVACÍ CHROMATOGRAFIE A HMOTNOSTNÍ SPEKTROMETRIE S INDUKČNĚ VÁZANÝM PLAZMATEM
KVANTITATIVNÍ ANALÝZA SPECIÍ JODU V BIOLOGICKÝCH VZORCÍCH SPOJENÍM VYLUČOVACÍ CHROMATOGRAFIE A HMOTNOSTNÍ SPEKTROMETRIE S INDUKČNĚ VÁZANÝM PLAZMATEM LUCIE HRUBÁ*, ANTONÍN KAŇA a OTO MESTEK Ústav analytické
IZOLACE, SEPARACE A DETEKCE PROTEINŮ I. Vlasta Němcová, Michael Jelínek, Jan Šrámek
IZOLACE, SEPARACE A DETEKCE PROTEINŮ I Vlasta Němcová, Michael Jelínek, Jan Šrámek Studium aktinu, mikrofilamentární složky cytoskeletu pomocí dvou metod: detekce přímo v buňkách - fluorescenční barvení
Elektroforéza v přítomnosti SDS SDS PAGE
Elektroforéza v přítomnosti SDS SDS PAGE Elektroforéza v přítomnosti SDS SDS PAGE je jednoduchá, rychlá a reprodukovatelná metoda pro kvalifikovanou charakterizaci a srovnání bílkovin.tato metoda separuje
Klinická a farmaceutická analýza. Petr Kozlík Katedra analytické chemie
Klinická a farmaceutická analýza Petr Kozlík Katedra analytické chemie e-mail: kozlik@natur.cuni.cz http://web.natur.cuni.cz/~kozlik/ 1 Spojení separačních technik s hmotnostní spektrometrem Separační
LABORATOŘ OBORU I ÚSTAV ORGANICKÉ TECHNOLOGIE (111) Použití GC-MS spektrometrie
LABORATOŘ OBORU I ÚSTAV ORGANICKÉ TECHNOLOGIE (111) C Použití GC-MS spektrometrie Vedoucí práce: Doc. Ing. Petr Kačer, Ph.D., Ing. Kamila Syslová Umístění práce: laboratoř 79 Použití GC-MS spektrometrie
APLIKOVANÉ ELEKTROMIGRAČNÍ METODY
APLIKOVANÉ ELEKTROMIGRAČNÍ METODY Princip: migrace elektricky nabitých částic v elektrickém poli Druhy iontů: +, -, obojaký (zwitterion), vícenásobný Typy migrace: a) přímá migrují ionty analytů b) nepřímá
Western blotting. 10% APS 20,28 µl 40,56 µl 81,12 µl 20,28 µl 40,56 µl 81,12 µl
Western blotting 1. Příprava gelu složení aparatury hustotu gelu volit podle velikosti proteinů příprava rozdělovacího gelu: 10% 12% počet gelů 1 2 4 1 2 4 objem 6 ml 12 ml 24 ml 6 ml 12 ml 24 ml 40% akrylamid
Hmotnostní spektrometrie. Historie MS. Schéma MS
Hmotnostní spektrometrie MS mass spectrometry MS je analytická technika, která se používá k měření poměru hmotnosti ku náboji (m/z) u iontů původně studium izotopového složení dnes dynamicky se vyvíjející
ÚSTAV CHEMIE A ANALÝZY POTRAVIN
VYSOKÁ ŠKOLA CHEMICKO-TECHNOLOGICKÁ V PRAZE ÚSTAV CHEMIE A ANALÝZY POTRAVIN Technická 5, 166 28 Praha 6 tel./fax.: + 420 220 443 185; jana.hajslova@vscht.cz LABORATOŘ Z ANALÝZY POTRAVIN A PŘÍRODNÍCH PRODUKTŮ
laktoferin BSA α S2 -CN α S1 -CN Popis: BSA bovinní sérový albumin, CN kasein, LG- laktoglobulin, LA- laktalbumin
Aktivita KA 2340/4-8up Stanovení bílkovin v mléce pomocí SDS PAGE (elektroforéza na polyakrylamidovém gelu s přídavkem dodecyl sulfátu sodného) vypracovala: MVDr. Michaela Králová, Ph.D. Princip: Metoda
Identifikace barviv pomocí Ramanovy spektrometrie
Identifikace barviv pomocí Ramanovy spektrometrie V kriminalistických laboratořích se provádí technická expertíza písemností, která se mimo jiné zabývá zkoumáním použitých psacích prostředků: tiskových
HMOTNOSTNÍ SPEKTROMETRIE
HMOTNOSTNÍ SPEKTROMETRIE MASS SPECTROMETRY (MS) Alternativní názvy (spojení s GC, LC, CZE, ITP): Hmotnostně spektrometrický (selektivní) detektor Mass spectrometric (selective) detector (MSD) Spektrometrie
KOMPLEXY EUROPIA(III) LUMINISCENČNÍ VLASTNOSTI A VYUŽITÍ V ANALYTICKÉ CHEMII. Pavla Pekárková
KOMPLEXY EUROPIA(III) LUMINISCENČNÍ VLASTNOSTI A VYUŽITÍ V ANALYTICKÉ CHEMII Pavla Pekárková Katedra analytické chemie, Přírodovědecká fakulta, Masarykova univerzita, Kotlářská 2, 611 37 Brno E-mail: 78145@mail.muni.cz
VYUŽITÍ TEPELNÉHO ZMLŽOVAČE V AAS
1 VYUŽITÍ TEPELNÉHO ZMLŽOVAČE V AAS JAN KNÁPEK Katedra analytické chemie, Přírodovědecká fakulta MU, Kotlářská 2, Brno 611 37 Obsah 1. Úvod 2. Tepelný zmlžovač 2.1 Princip 2.2 Konstrukce 2.3 Optimalizace
nano.tul.cz Inovace a rozvoj studia nanomateriálů na TUL
Inovace a rozvoj studia nanomateriálů na TUL nano.tul.cz Tyto materiály byly vytvořeny v rámci projektu ESF OP VK: Inovace a rozvoj studia nanomateriálů na Technické univerzitě v Liberci Experimentální
SDS-PAGE elektroforéza
SDS-PAGE elektroforéza Příprava gelu... 1 Recept na 0.75 mm gel (1 gel/2 gely)... 2 Recept na 1.5 mm gel (1 gel/2 gely)... 2 Příprava vzorku... 3 Elektroforéza... 3 Barvení gelů Blue Silver... 4 Chemikálie
Emise vyvolaná působením fotonů nebo částic
Emise vyvolaná působením fotonů nebo částic PES (fotoelektronová spektroskopie) XPS (rentgenová fotoelektronová spektroskopie), ESCA (elektronová spektroskopie pro chemickou analýzu) UPS (ultrafialová
Hmotnostní detekce v separačních metodách
Hmotnostní detekce v separačních metodách MC230P83 2/1 Z+Zk 4 kredity doc. RNDr. Josef Cvačka, Ph.D. Mgr. Martin Hubálek, Ph.D. Ústav organické chemie a biochemie AVČR, v.v.i. Flemingovo nám. 2, 166 10
PROTOKOL WESTERN BLOT
WESTERN BLOT 1. PŘÍPRAVA ELEKTROFORETICKÉ APARATURY Saponátem a vodou se důkladně umyjí skla, plastové vložky a hřebínek, poté se důkladně opláchnou deionizovanou/destilovanou vodou a etanolem a nechají
Molekulová spektroskopie 1. Chemická vazba, UV/VIS
Molekulová spektroskopie 1 Chemická vazba, UV/VIS 1 Chemická vazba Silová interakce mezi dvěma atomy. Chemické vazby jsou soudržné síly působící mezi jednotlivými atomy nebo ionty v molekulách. Chemická
Příprava materiálu byla podpořena projektem OPPA č. CZ.2.17/3.1.00/33253
Příprava materiálu byla podpořena projektem OPPA č. CZ.2.17/3.1.00/33253 Část 16 Iontová chromatografie Iontová chromatografie je speciální technika vyvinutá pro separaci anorganických iontů a organických
HMOTNOSTNÍ SPEKTROMETRIE
HMOTNOSTNÍ SPEKTROMETRIE A MOŽNOSTI JEJÍHO SPOJENÍ SE SEPARAČNÍMI METODAMI SEPARACE chromatografie CGC, GC x GC HPLC, UPLC, UHPLC, CHIP-LC elektromigrační m. CZE, CITP INTERFACE SPOJENÍ x ROZHRANÍ GC vyhřívaná
ELEKTROFORETICKÉ METODY
ELEKTROFORETICKÉ METODY ELEKTROFORETICKÁ SEPARACE AMINOKYSELIN NA PAPÍROVÉM NOSIČI Aminokyseliny lze rozdělit elektroforézou na papíře. Protože molekulová hmotnost jednotlivých aminokyselin není příliš
Porovnání metod atomové spektrometrie
Porovnání metod atomové spektrometrie ACH/APAS David MILDE, 2017 Úvod Metody našeho zájmu: plamenová atomizace v AAS (FA-AAS) elektrotermická atomizace v AAS (ETA-AAS, GF-AAS) ICP-OES ICP-MS Výhody a nevýhody
Přímá analýza reálných vzorků hmotnostní spektrometrií s využitím nanodesorpčního elektrospreje (nano-desi-ms)
Přímá analýza reálných vzorků hmotnostní spektrometrií s využitím nanodesorpčního elektrospreje (nano-desi-ms) Teorie: Desorpční elektrosprej (DESI) byl popsán v roce 2004 Zoltánem Takátsem. Jedná se o
Renáta Kenšová. Název: Školitel: Datum: 24. 10. 2014
Název: Školitel: Sledování distribuce zinečnatých iontů v kuřecím zárodku za využití moderních technik Monitoring the distribution of zinc ions in chicken embryo using modern techniques Renáta Kenšová
Optický emisní spektrometr Agilent 725 ICP-OES
Optický emisní spektrometr Agilent 725 ICP-OES Popis systému: Přístroj, včetně řídicího softwaru a počítače, určený pro plně simultánní stanovení prvků v širokém koncentračním rozmezí (ppm až %), v nejrůznějších
Spojení hmotové spektrometrie se separačními metodami
Spojení hmotové spektrometrie se separačními metodami RNDr. Radomír Čabala, Dr. Katedra analytické chemie Přírodovědecká fakulta Univerzita Karlova Praha Spojení hmotové spektrometrie se separačními metodami
Inovace bakalářského studijního oboru Aplikovaná chemie CZ.1.07/2.2.00/
Dělení bílkovin pomocí diskontinuální elektroforézy v polyakrylamidovém gelu (PAGE) Při elektroforéze dochází k pohybu (migraci) iontů v elektrickém poli. Elektroforetické metody se tedy používají k separaci
PROTEINOVÁ DENATURUJÍCÍ ELEKTROFORÉZA (SDS PAGE)
PROTEINOVÁ DENATURUJÍCÍ ELEKTROFORÉZA (SDS PAGE) Denaturující proteinová elektroforéza (SDS PAGE - SDS Protein Acrylamide Gel Electrophoresis) je metoda, která se používá k separaci proteinů podle velikosti,
Separační metody v analytické chemii. Plynová chromatografie (GC) - princip
Plynová chromatografie (GC) - princip Plynová chromatografie (Gas chromatography, zkratka GC) je typ separační metody, kdy se od sebe oddělují složky obsažené ve vzorku a které mohou být převedeny do plynné
NOVÝ SORPČNÍ GEL NA BÁZI SPHERON-OXINU PRO UŽITÍ V TECHNICE DGT. Michaela Gregušová
NOVÝ SORPČNÍ GEL NA BÁZI SPHERON-OXINU PRO UŽITÍ V TECHNICE DGT Michaela Gregušová Ústav chemie a technologie ochrany životního prostředí, Fakulta chemická, Vysoké učení technické v Brně, Purkyňova 118,
Metody povrchové analýzy založené na detekci iontů. Pavel Matějka
Metody povrchové analýzy založené na detekci iontů Pavel Matějka Metody povrchové analýzy založené na detekci iontů 1. sekundárních iontů - SIMS 1. Princip metody 2. Typy bombardování 3. Analyzátory iontů
Světlo jako elektromagnetické záření
Světlo jako elektromagnetické záření Základní pojmy: Homogenní prostředí prostředí, jehož dané vlastnosti jsou ve všech místech v prostředí stejné. Izotropní prostředí prostředí, jehož dané vlastnosti
Aplikace elektromigračních technik Laboratorní úlohy
Laboratorní úlohy Výukový materiál vznikl za finanční podpory Fondu rozvoje vysokých škol v rámci řešení projektu č. 1377/2013 Vytvoření demonstračních úloh sloužících k inovaci předmětu Aplikace elektromigračních
ELEKTROFORETICKÁ SEPARACE NUKLEOVÝCH KYSELIN
ELEKTROFORETICKÁ SEPARACE NUKLEOVÝCH KYSELIN Fragmenty nukleových kyselin lze dle jejich velikosti rozdělit elektroforézou. Elektroforéza využívá rozdílné pohyblivosti jednotlivých fragmentů, danou právě
10. Tandemová hmotnostní spektrometrie. Princip tandemové hmotnostní spektrometrie
10. Tandemová hmotnostní spektrometrie Princip tandemové hmotnostní spektrometrie Informace získávané při tandemové hmotnostní spektrometrii Možné způsoby uspořádání tandemové HS a/ scan fragmentů vzniklých
Chemické veličiny, vztahy mezi nimi a chemické výpočty
SBÍRKA ŘEŠENÝCH PŘÍKLADŮ PRO PROJEKT PŘÍRODNÍ VĚDY AKTIVNĚ A INTERAKTIVNĚ CZ.1.07/1.1.24/01.0040 Chemické veličiny, vztahy mezi nimi a chemické výpočty Mgr. Jana Žůrková, 2013, 20 stran Obsah 1. Veličiny
TECHNICKÁ SPECIFIKACE Vybavení genetické laboratoře pro projekt EXTEMIT-K část B
TECHNICKÁ SPECIFIKACE Vybavení genetické laboratoře pro projekt EXTEMIT-K část B OBSAH Sestava pro vertikální elektroforézu... 2 Jednotka pro elektroforézu... 3 Termocykler... 4 Elektrický zdroj pro elektroforézu...
Hmotový spektrometr s indukčně vázaným plasmatem (ICPMS) II (opakovaná)
Odůvodnění veřejné zakázky dle 156 zákona č. 137/2006 Sb., o veřejných zakázkách, v platném znění (dále jen ZVZ ) a vyhlášky č. 232/2012 Sb., o podrobnostech rozsahu odůvodnění účelnosti veřejné zakázky
Chem. Listy 105, (2011)
VYUŽITÍ DYNAMICKÉ REAKČNÍ CELY PRO STANOVENÍ FOSFORU METODOU HMOTNOSTNÍ SPEKTROMETRIE S INDUKČNĚ VÁZANÝM PLAZMATEM ANTONÍN KAŇA* a OTO MESTEK Ústav analytické chemie, Fakulta chemicko-inženýrská, Vysoká
ATOMOVÁ SPEKTROMETRIE
ATOMOVÁ SPEKTROMETRIE doc. Ing. David MILDE, Ph.D. tel.: 585634443 E-mail: david.milde@upol.cz (c) -017 Doporučená literatura Černohorský T., Jandera P.: Atomová spektrometrie. Univerzita Pardubice 1997.
Agilent 5110 ICP-OES vždy o krok napřed
analytická instrumentace, PC, periferie, služby, poradenství, servis Agilent 5110 ICP-OES vždy o krok napřed FACT Jedinečný nástroj pro korekce spektrálních interferencí. V dokonalém světě by ICP-OES spektrometry
Pražské analytické centrum inovací Projekt CZ / /0002 spolufinancovaný ESF a Státním rozpočtem ČR
Pražské analytické centrum inovací Projekt CZ.04.3.07/4.2.01.1/0002 spolufinancovaný ESF a Státním rozpočtem ČR SEPARACE PROTEINŮ Preparativní x analytická /měřítko, účel/ Zvláštnosti dané povahou materiálu
Vizualizace DNA ETHIDIUM BROMID. fluorescenční barva interkalační činidlo. do gelu do pufru barvení po elfu SYBR GREEN
ETHIDIUM BROMID fluorescenční barva interkalační činidlo do gelu do pufru barvení po elfu Vizualizace DNA SYBR GREEN Barvení proteinů Coommassie Brilliant Blue Coomassie Blue x barvení stříbrem Porovnání
1/10/2014. Kapilární elektroforéza s hmotnostní detekcí. Historie
Spřažené techniky (1. část) Historie Kapilární elektroforéza s hmotnostní detekcí K. Záruba kapilární elektroforéza + Jorgenson, Lukacs, 1981 (Jorgenson, J. W., Lukacs, K. D., Anal. Chem. 1981, 53, 1298
Příloha č. 1 k MP č. 04/14. Datum účinnosti. Identifikace metody (SOP) Zk.č. 1 M-CH 01 Stanovení teploty ČSN
1 M-CH 01 Stanovení teploty ČSN 757342 1.8.2013 2 M-CH 02 Stanovení barvy 7887 1.8.2012 3 M-CH 03 Stanovení zákalu 7027 1.1.2001 4 M-CH 04 Stanovení elektrické konduktivity ČSN EN 27888 1.7.1996 5 M-CH
INTERAKCE IONTŮ S POVRCHY II.
Úvod do fyziky tenkých vrstev a povrchů INTERAKCE IONTŮ S POVRCHY II. Metody IBA (Ion Beam Analysis): pružný rozptyl nabitých částic (RBS), detekce odražených atomů (ERDA), metoda PIXE, Spektroskopie rozptýlených
Jednotné pracovní postupy zkoušení krmiv STANOVENÍ OBSAHU SELENU METODOU ICP-OES
Strana 1 STANOVENÍ OBSAHU SELENU METODOU ICP-OES 1 Rozsah a účel Postup specifikuje podmínky pro stanovení celkového obsahu selenu v minerálních krmivech a premixech metodou optické emisní spektrometrie
Inovace bakalářského studijního oboru Aplikovaná chemie CZ.1.07/2.2.00/ Výpočty z chemických vzorců
Výpočty z chemických vzorců 1. Hmotnost kyslíku je 80 g. Vypočítejte : a) počet atomů kyslíku ( 3,011 10 atomů) b) počet molů kyslíku (2,5 mol) c) počet molekul kyslíku (1,505 10 24 molekul) d) objem (dm
OPTICKÁ EMISNÍ SPEKTROMETRIE
OPTICKÁ EMISNÍ SPEKTROMETRIE Optical Emission Spectrometry (OES) ATOMOVÁ EMISNÍ SPEKTROMETRIE (AES) (c) -2010 OES je založena na registrování fotonů vzniklých přechody valenčních e - z vyšších energetických
13. Kolik molů vodíku vznikne reakcí jednoho molu zinku s kyselinou chlorovodíkovou?
Hmotnosti atomů a molekul, látkové množství - 1. ročník 1. Vypočítej skutečnou hmotnost jednoho atomu železa. 2. Vypočítej látkové množství a) S v 80 g síry, b) S 8 v 80 g síry, c) H 2 S v 70 g sulfanu.
N A = 6,023 10 23 mol -1
Pro vyjadřování množství látky se v chemii zavádí veličina látkové množství. Značí se n, jednotkou je 1 mol. Látkové množství je jednou ze základních veličin soustavy SI. Jeden mol je takové množství látky,
ISOLATION OF PHOSPHOPROTEOM AND ITS APPLICATION IN STUDY OF THE EFFECT OF CYTOKININ ON PLANTS
ISOLATION OF PHOSPHOPROTEOM AND ITS APPLICATION IN STUDY OF THE EFFECT OF CYTOKININ ON PLANTS IZOLACE FOSFOPROTEOMU A JEHO VYUŽITÍ PŘI STUDIU ÚČINKU CYTOKININŮ NA ROSTLINU Černý M., Brzobohatý B. Department
1. Příloha 1 Návod úlohy pro Pokročilé praktikum z biochemie I
1. Příloha 1 Návod úlohy pro Pokročilé praktikum z biochemie I Vazba bromfenolové modři na sérový albumin Princip úlohy Albumin má unikátní vlastnost vázat menší molekuly mnoha typů. Díky struktuře, tvořené
ANALÝZA EXTRAKTU PODLE MEHLICHA 3 METODOU ICP-OES
30074. Analýza extraktu podle Mehlicha 3 Strana ANALÝZA EXTRAKTU PODLE MEHLICHA 3 METODOU ICP-OES Účel a rozsah Postup je určen především pro stanovení obsahu základních živin vápníku, hořčíku, draslíku,
Inhibitory koroze kovů
Inhibitory koroze kovů Úvod Korozní rychlost kovových materiálů lze ovlivnit úpravou prostředí, ve kterém korozní děj probíhá. Mezi tyto úpravy patří i použití inhibitorů koroze kovů. Inhibitor je látka,
Vazby v pevných látkách
Vazby v pevných látkách Hlavní body 1. Tvorba pevných látek 2. Van der Waalsova vazba elektrostatická interakce indukovaných dipólů 3. Iontová vazba elektrostatická interakce iontů 4. Kovalentní vazba
Základy NIR spektrometrie a její praktické využití
Nicolet CZ s.r.o. The world leader in serving science Základy NIR spektrometrie a její praktické využití NIR praktická metoda molekulové spektroskopie, nahrazující pracnější, časově náročnější a dražší
Inovativní výrobky a environmentální technologie (reg. č. CZ.1.05/3.1.00/ ) ENVITECH
Inovativní výrobky a environmentální technologie (reg. č. CZ.1.05/3.1.00/14.0306) ENVITECH Zpráva o řešení IA 05 Optimalizace užitných vlastností procesních kapalin s využitím nanostruktur Vedoucí aktivity:
SEZNAM PŘÍLOH 11. SEZNAM PŘÍLOH
SEZNAM PŘÍLOH 11. SEZNAM PŘÍLOH Příloha 1 Výrobní systémy prášku VIGA, EIGA a PIGA... 84 Příloha 2 Proudění bublin v tavící lázni... 84 Příloha 3 Graf hodnot BFE pro různé mísící poměry prášků... 85 Příloha
Chromatografie. Petr Breinek
Chromatografie Petr Breinek Chromatografie-I 2012 Společným znakem všech chromatografických metod je kontinuální dělení složek analyzované směsi mezi dvěma fázemi. Pohyblivá fáze (mobilní), eluent Nepohyblivá
Valenční elektrony a chemická vazba
Valenční elektrony a chemická vazba Ve vnější energetické hladině se nacházejí valenční elektrony, které se mohou podílet na tvorbě chemické vazby. Valenční elektrony často znázorňujeme pomocí teček kolem
ZÁKLADNÍ CHEMICKÉ VÝPOČTY
ZÁKLADNÍ CHEMICKÉ VÝPOČTY Látkové množství - vyjadřování množství: jablka pivo chleba uhlí - (téměř každá míra má svojí jednotku) v chemii existuje univerzální veličina pro vyjádření množství látky LÁTKOVÉ
5. Jaká bude koncentrace roztoku hydroxidu sodného připraveného rozpuštěním 0,1 molu látky v baňce o objemu 500 ml. Vyber správný výsledek:
ZÁKLADNÍ CHEMICKÉ VÝPOČTY II. autoři a obrázky: Mgr. Hana a Radovan Sloupovi 1. Ve třech válcích byly plyny, prvky. Válce měly obsah 3 litry. Za normálních podmínek obsahoval první válec bezbarvý plyn
IONOSEP v analýze vody. Využití analyzátorů IONOSEP pro analýzu vod. Doc. Ing. František KVASNIČKA, CSc.
Využití analyzátorů IONOSEP pro analýzu vod Doc. Ing. František KVASNIČKA, CSc. IONOSEP v analýze vody Kapilární isotachoforesa nebo její kombinace se zónovou elektroforesou je svými vlastnostmi velmi
NSZ 1 ENVFATE VCP 1.3 FATESPECMET. D1 Viktor KANICKÝ (0,5)
NSZ 1 ENVFATE VCP 1.3 FATESPECMET D1 Viktor KANICKÝ (0,5) D1 Josef KOMÁREK (0,5), D1 Jiří MACHÁT (0,5) D1 Markéta HOLÁ (1,0), D1 Eva NIEDOBOVÁ (1,0) D2 Jitka STUDÝNKOVÁ-HEGROVÁ (1,0) 2000 Laboratoř atomové
Univerzita Pardubice 8. licenční studium chemometrie
Univerzita Pardubice 8. licenční studium chemometrie Statistické zpracování dat při managementu jakosti Semestrální práce Výpočet nejistoty analytického stanovení Ing. Jan Balcárek, Ph.D. vedoucí Centrálních
Experimentální biologie Bc. chemie
Experimentální biologie Bc. chemie 1. značte prvek s největší elektronegativitou: a) draslík b) chlor c) uhlík d) vápník e) fluor 3. Mezi p prvky nepatří: a) P b) As c) Fe d) B e) Si 4. Radioaktivní záření
Třífázové trubkové reaktory se zkrápěným ložem katalyzátoru. Předmět: Vícefázové reaktory Jméno: Veronika Sedláková
Třífázové trubkové reaktory se zkrápěným ložem katalyzátoru Předmět: Vícefázové reaktory Jméno: Veronika Sedláková 3-fázové reakce Autoklávy (diskontinuální) Trubkové reaktory (kontinuální) Probublávané
Ultrastopová laboratoř České geologické služby
Ultrastopová laboratoř České geologické služby Jitka Míková Česká geologická služba Praha - Barrandov Laboratorní koloběh Zadavatel TIMS Analýza vzorku Vojtěch Erban Jakub Trubač Lukáš Ackerman Jitka Míková
Studijní program: Analytická a forenzní chemie
Studijní program: Analytická a forenzní chemie Studijní program: Analytická a forenzní chemie První rok je studium společné a dělí se až od druhého roku na specializace Specializace 1: Analytická chemie,
Speciální spektrometrické metody. Zpracování signálu ve spektroskopii
Speciální spektrometrické metody Zpracování signálu ve spektroskopii detekce slabých signálů synchronní detekce (Lock-in) čítaní fotonů měření časového průběhu signálů metoda fázového posuvu časově korelované
Test vlastnosti látek a periodická tabulka
DUM Základy přírodních věd DUM III/2-T3-2-08 Téma: Test vlastnosti látek a periodická tabulka Střední škola Rok: 2012 2013 Varianta: A Zpracoval: Mgr. Pavel Hrubý Mgr. Josef Kormaník TEST Test vlastnosti
Vyjadřuje poměr hmotnosti rozpuštěné látky k hmotnosti celého roztoku.
Koncentrace roztoků Hmotnostní zlomek w Vyjadřuje poměr hmotnosti rozpuštěné látky k hmotnosti celého roztoku. w= m A m s m s...hmotnost celého roztoku, m A... hmotnost rozpuštěné látky Hmotnost roztoku
DOUTNAVÝ VÝBOJ. Další technologie využívající doutnavý výboj
DOUTNAVÝ VÝBOJ Další technologie využívající doutnavý výboj Plazma doutnavého výboje je využíváno v technologiích depozice povlaků nebo modifikace povrchů. Jedná se zejména o : - depozici povlaků magnetronovým
Stanovení 14 C s využitím urychlovačové hmotnostní spektrometrie (AMS)
Stanovení 14 C s využitím urychlovačové hmotnostní spektrometrie (AMS) Fejgl 1,2, M., Černý 1,3, R., Světlík 1,2, I., Tomášková 1, L. 1 CRL ODZ ÚJF AV ČR, v.v.i., Na Truhlářce 39/64, 180 86 Praha 8 2 SÚRO,
Elektromigrační metody
Elektromigrační metody Princip: molekuly nesoucí náboj se pohybují ve stejnosměrném elektrickém Arne Tiselius rozdělil proteiny krevního séra na základě jejich rozdílných rychlostí pohybu v elektrickém
CHEMICKÉ VÝPOČTY I. ČÁST LÁTKOVÉ MNOŽSTVÍ. HMOTNOSTI ATOMŮ A MOLEKUL.
CHEMICKÉ VÝPOČTY I. ČÁST LÁTKOVÉ MNOŽSTVÍ. HMOTNOSTI ATOMŮ A MOLEKUL. Látkové množství Značka: n Jednotka: mol Definice: Jeden mol je množina, která má stejný počet prvků, jako je atomů ve 12 g nuklidu
Identifikace a stanovení chininu v toniku pomocí CE-MS
Identifikace a stanovení chininu v toniku pomocí CE-MS Úkol: Stanovte množství chininu v nealkoholickém nápoji (tonik) pomocí kapilární zónové elektroforézy ve spojení s hmotnostní spektrometrií Teoretická
AUTOMATICKÁ EMISNÍ SPEKTROMETRIE
AUTOMATICKÁ EMISNÍ SPEKTROMETRIE SPEKTROGRAFIE Jako budící zdroj slouží plazma elektrického výboje, kdy se výkon generátoru mění v plazmatu na teplo, ionizační a budící práci a zářivou E. V praxi se spektrografie
Hmotnostní spektrometrie
Hmotnostní spektrometrie Podstatou hmotnostní spektrometrie je studium iontů v plynném stavu. Tato metoda v sobě zahrnuje tři hlavní části:! generování iontů sledovaných atomů nebo molekul! separace iontů
Hmotnostní spektrometrie ve spojení se separačními metodami
Pražské analytické centrum inovací Projekt CZ.04.3.07/4.2.01.1/0002 spolufinancovaný ESF a Státním rozpočtem ČR Hmotnostní spektrometrie ve spojení se separačními metodami Ivan Jelínek PřF UK Praha Definice:
NÁVOD K POUŽITÍ VÁPNÍK 600 KATALOGOVÉ ČÍSLO 207
NÁVOD K POUŽITÍ VÁPNÍK 600 KATALOGOVÉ ČÍSLO 207 POUŽITÍ Souprava Vápník 600 se používá ke kvantitativnímu stanovení koncentrace vápenatých iontů v séru a moči. SOUHRN V lidském organismu je vázána převážná
Hmotnostní spektrometrie - Mass Spectrometry (MS)
Hmotnostní spektrometrie - Mass Spectrometry (MS) Další pojem: Hmotnostně spektrometrický (selektivní) detektor - Mass spectrometric (selective) detector (MSD) Spektrometrie - metoda založená na interakci
Identifikace zkušebního postupu/metody PP 621 1.01 (ČSN ISO 9556, ČSN ISO 4935) PP 621 1.02 (ČSN EN 10276-2, ČSN 42 0525)
List 1 z 9 Pracoviště zkušební laboratoře: Odd. 621 Laboratoř chemická, fázová a korozní Protokoly o zkouškách podepisuje: Ing. Karel Malaník, CSc. ředitel Laboratoří a zkušeben Ing. Vít Michenka zástupce
Struktura bílkovin očima elektronové mikroskopie
Struktura bílkovin očima elektronové mikroskopie Roman Kouřil Katedra Biofyziky (http://biofyzika.upol.cz) Centrum regionu Haná pro biotechnologický a zemědělský výzkum Přírodovědecká fakulta, Univerzita